header

Evaluation of the accuracy of cone beam computed tomography-based registration and multislice computed tomography-based registration for oral and maxillofacial surgery : (Record no. 59910)

MARC details
000 -LEADER
fixed length control field 02936cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031652.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170220s2016 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.13.Ph.D.2016.Ya.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Yara Rabia Mohamed Ali Helaly
245 10 - TITLE STATEMENT
Title Evaluation of the accuracy of cone beam computed tomography-based registration and multislice computed tomography-based registration for oral and maxillofacial surgery :
Remainder of title In vitro study /
Statement of responsibility, etc. Yara Rabia Mohamed Ali Helaly ; Supervised Mushira Mohamed Dahaba , Hany Mahmoud Omar , Mohamed Khalifa Zayet
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم دقة المطابقة بالحاسوب مخروطية الشعاع و المطابقة بحاسوب الأشعة المقطعية لجراحة الوجة و الفكين :
Remainder of title دراسة مختبرية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Yara Rabia Mohamed Ali Helaly ,
Date of publication, distribution, etc. 2016
300 ## - PHYSICAL DESCRIPTION
Extent 104 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery
520 ## - SUMMARY, ETC.
Summary, etc. Objectives: Multislice computed tomography and cone beam computed tomography scans data are used at a variety of applications in medical and dental fields. Among these applications is image registration that has become an essential step in medical images processing as radiation therapy, oral and maxillofacial surgery, orthodontics, {u2026}etc,. The aim of this study was to evaluate the accuracy of MSCT- and CBCT- based registration for oral and maxillofacial surgery on dry human mandibles. Materials and Methods: The current study comprised ten dry human mandibles scanned twice using a MSCT scanner and scanned twice using a CBCT scanner. The registration accuracy was evaluated by superimposing both images sets for each mandible (of the same modality) then measuring the distance between the two images at definite points. This was done with both modalities. To compare various point based registration techniques, the two images of the same mandible were superimposed three times with different registration points; bone landmarks, dental landmarks, and fiducial markers then the distance between the two images was measured for the three techniques. This was done with both modalities. Results: The results of the current study demonstrated that CBCT showed lower mean discrepancy in the measurements than MSCT
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Cone beam computed tomography
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Multislice computed tomography
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Registration
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hany Mahmoud Omar ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Khalifa Zayet ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mushira Mohamed Dahaba ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Enas
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.13.Ph.D.2016.Ya.E 01010110070904000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.13.Ph.D.2016.Ya.E 01020110070904000 22.09.2023 CD - Rom 70904.CD