header

The single 2.0mm Ao locking reconstruction plate versus the conventional plate system in treating two lines of linear mandibular Fracture = (Record no. 60251)

MARC details
000 -LEADER
fixed length control field 03247cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031702.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170314s2014 ua h f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.13.M.Sc.2014.Mo.S
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohammed Adel Abdelfattah Mohammed
245 14 - TITLE STATEMENT
Title The single 2.0mm Ao locking reconstruction plate versus the conventional plate system in treating two lines of linear mandibular Fracture =
Remainder of title استخدام الشرائح التثبيتيه المفرده ذات الإطباق بسمك 2مم ضد الشرائح العاديه فى علاج الكسور الخطيه للفك السفلى فى مكانين /
Statement of responsibility, etc. Mohammed Adel Abdelfattah Mohammed ; Supervised Kadri Mohamed Nasr , Hassan Gamal Sadek
246 15 - VARYING FORM OF TITLE
Title proper/short title استخدام الشرائح التثبيتيه المفرده ذات الإطباق بسمك 2مم ضد الشرائح العاديه فى علاج الكسور الخطيه للفك السفلى فى مكانين
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mohammed Adel Abdelfattah Mohammed ,
Date of publication, distribution, etc. 2014
300 ## - PHYSICAL DESCRIPTION
Extent 80 P. :
Other physical details facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery
520 ## - SUMMARY, ETC.
Summary, etc. This study was conducted to compare between the rigidity of fixation between conventional 2mm plates and the reconstruction 2mm plates in cases of two lines of linear mandibular fracture. The results assessed by degree of bone density through radiographic evaluation preoperatively then immediately postoperatively, one month, two months, three months postoperatively. A total of 10 patients suffered from 2 lines of linear mandibular fracture divided into 2 groups five patients each. Group (A) treated with conventional 2mm plates and screws two plates for each fracture line (rigid fixation). Group (B) treated with locking 2mm plates and locking head screws one plate for each fracture line, three screws on each side of the fracture line (rigid fixation). Data collected by radiographic images taken preoperatively , one month, two months, three months postoperatively. Digitalized images were manipulated using the specially designed software of the digora system. On each digital image, the mean gray value of the marked region of interest was calculated using the line measurement facility of the software. This was performed by drawing lines along the whole length of the fracture line. The clinical results assessed infection rate, range on mandibular movement, post operative numbness and wound dehiscence. No signs of infection or wound dehiscence recorded throughout the follow up period, range of mandibular movement increased from 19-24mm preoperatively to 22-26mm immediately postoperatively to 40-45mm by the end three months postoperatively
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Locking plates
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Mandibular fracture
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Rigid fixation
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hassan Gamal Sadek ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Kadri Mohamed Nasr ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.13.M.Sc.2014.Mo.S 01010110071288000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.13.M.Sc.2014.Mo.S 01020110071288000 22.09.2023 CD - Rom 71288.CD