header

Potentiometeric determination of cobalt (II) and cadmium (II) ions in real samples / (Record no. 60725)

MARC details
000 -LEADER
fixed length control field 01969cam a2200313 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170429s2016 ua h f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.12.08.M.Sc.2016.No.P
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Noha Mohsen Hanafy Mahmoud
245 10 - TITLE STATEMENT
Title Potentiometeric determination of cobalt (II) and cadmium (II) ions in real samples /
Statement of responsibility, etc. Noha Mohsen Hanafy Mahmoud ; Supervised Mohamed Mohamed Omar , Tamer Awad Ali
246 15 - VARYING FORM OF TITLE
Title proper/short title التقدير الجهدى لأيونات الكوبالت و الكادميوم فى العينات الحقيقية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Noha Mohsen Hanafy Mahmoud ,
Date of publication, distribution, etc. 2016
300 ## - PHYSICAL DESCRIPTION
Extent 102 P. :
Other physical details facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Science - Department of Analytical Chemistry
520 ## - SUMMARY, ETC.
Summary, etc. In this study, two proposed modified carbon paste electrodes (CPE) with schiff bases or metal complexes as ionophore were described for determination of cobalt(II) and cadmium(II) ions in pure and real samples. The carbon paste electrodes were characterized and optimized with respect to the main experimental parameters affecting the electrode performance, including composition, pH, temperature, response time and interferences. The electrodes showed good selectivity for cobalt(II) and cadmium (II) ions with respect to some inorganic cations and anions. The developed electrodes have been used successfully for the determination of cobalt and cadmium in some real samples using calibration method. The obtained results were in good agreement with those obtained using the official method
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Cadmium
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Carbon paste electrodes
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Cobalt
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Mohamed Omar ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Tamer Awad Ali ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.12.08.M.Sc.2016.No.P 01010110071591000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.12.08.M.Sc.2016.No.P 01020110071591000 22.09.2023 CD - Rom 71591.CD