Effect of continuous versus pulsed ultrasound on myofascial pain syndrome / (Record no. 60803)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03254cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223031720.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 170507s2016 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.21.09.M.Sc.2016.He.E |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Heba-Allah Samy Said Ahmed |
245 10 - TITLE STATEMENT | |
Title | Effect of continuous versus pulsed ultrasound on myofascial pain syndrome / |
Statement of responsibility, etc. | Heba-Allah Samy Said Ahmed ; Supervised Awatef Mohamed Labib , Olfat Ibrahim Ali |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | تأثير الموجات فوق الصوتية المستمرة مقابل المتقطعة في الألم الليفي العضلي |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Heba-Allah Samy Said Ahmed , |
Date of publication, distribution, etc. | 2016 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 104 P. : |
Other physical details | charts , facsimiles ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Physical Therapy - Department of Basic Science |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Background: Myofascial pain syndrome (MPS) is a complex pain syndrome characterized with trigger points (TrPs) in skeletal muscles. Ultrasound (US) therapy is one of the main devices used in physical therapy, for the treatment of TrPs in MPS. Purpose: This study aimed to compare between continuous, pulsed (1:1 &1:4) and sham ultrasound in subjects with myofascial trigger points in the upper fibers of trapezius muscle. Subjects: Sixty subjects (37 males and 23 females) with active trigger points on the upper fibers of trapezius, aged 18 to 30 years participated in the study. Methods: Subjects were randomly divided into four equal groups, including Group A was treated with continuous ultrasound (3MHz, 1W/cm²), Group B was treated with pulsed ultrasound (3MHz, 1W/cm², 1:1 ratio), Group C was treated with pulsed ultrasound (3MHz, 1W/cm², 1:4 ratio), and Group D, the control group, was treated with sham ultrasound. All treatments applied 5 minutes 5 days per week for 2 weeks. Pressure pain threshold (PPT) was assessed with pressure algometer, pain severity was assessed with visual analog scale (VAS) and quality of life was evaluated with Nottingham health profile (NHP). All evaluations were performed before and after 10 sessions of treatment. Results: There was a significant difference between group (A) and other groups according to PPT as p value (p<0.05). There was a significant difference between group (A) and (C) & (D) according to VAS and NHP as p value (p<0.05). There was a significant difference between group (B) and other groups according to PPT as p value (P<0.05) and no significant difference according to VAS and NHP. There was no significant difference between group (C) and (D) according to PPT, VAS and NHP. Conclusion: Continuous and pulsed (1:1) ultrasound are more effective than pulsed (1:4) and sham ultrasound in the treatment of myofascial pain syndrome. Continuous ultrasound show more improvement than pulsed ultrasound |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Myofascial pain syndrome |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Trigger points |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Ultrasound |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Awatef Mohamed Labib , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Olfat Ibrahim Ali , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Enas |
Reviser | Cataloger |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.21.09.M.Sc.2016.He.E | 01010110070947000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.21.09.M.Sc.2016.He.E | 01020110070947000 | 22.09.2023 | CD - Rom | 70947.CD |