header

Computer assisted lag screw placement in anterior mandibular fractures / (Record no. 61213)

MARC details
000 -LEADER
fixed length control field 02605cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031732.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170614s2015 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.13.M.Sc.2015.Mo.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohamed Kadry Nasr Geaisa
245 10 - TITLE STATEMENT
Title Computer assisted lag screw placement in anterior mandibular fractures /
Statement of responsibility, etc. Mohamed Kadry Nasr Geaisa ; Supervised Hesham Abdelhakam , Adel Hamdy Abou Elfetouh
246 15 - VARYING FORM OF TITLE
Title proper/short title مساعدة الحاسوب في ضع المسمارالربط في كسور الفك السفلي الأمامي
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mohamed Kadry Nasr Geaisa ,
Date of publication, distribution, etc. 2015
300 ## - PHYSICAL DESCRIPTION
Extent 104 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery
520 ## - SUMMARY, ETC.
Summary, etc. From this study it could be concluded that: 1- Lag applied rapidly with no waste of time for adaptation of the plate allowing more anatomical reduction without reduction in rigidity . 2- Anatomically lag screws provided accurate reduction, especially in sagital fractures 3- The cost of lag screws are cheaper than bone plates. 4- Less implant material and Shortening the time of operation. 5- Less surgical exposure, sub periosteal dissection and degloving of the periosteum in comparison to bone plates. 6- Lag screws Lack of stress shielding principle (which is present with compression plates. where functional forces instead of being distributed through the center of the bone pass through and are absorbed by the plate and the cortex to which the plate has been attached resulting in a local unloading of the bone and subsequent bone porosis). Therefore lag screws do not require further removal. 7- The lag screw is the strongest and the stiffest in comparison to locking and non locking mini plates and compression plates. Hence lag screw provide better mechanical properties in comparison with other plating systems The use of computer guided technology provided a signi{uFB01}cant advancement and improvement in the {uFB01}eld of osteosynthesis
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Anterior mandibular fractures
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Computer assisted lag screw placement
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Oral and Maxillofacial Surgery
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Adel Hamdy Abouelfetouh ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hesham Abdelhakam ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Enas
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.13.M.Sc.2015.Mo.C 01010110071845000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.13.M.Sc.2015.Mo.C 01020110071845000 22.09.2023 CD - Rom 71845.CD