header

Numerical analysis of indoor air quality in clinical pharmacies / (Record no. 61469)

MARC details
000 -LEADER
fixed length control field 01889cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170708s2016 ua o f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.11.Ph.D.2016.Ra.N
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Rana Essam Eldin Khalil Hassan Khalil
245 10 - TITLE STATEMENT
Title Numerical analysis of indoor air quality in clinical pharmacies /
Statement of responsibility, etc. Rana Essam Eldin Khalil Hassan Khalil ; Supervised Samy M. Morcos , Mohamed Aly Hassan , Esmail M. Bialy
246 15 - VARYING FORM OF TITLE
Title proper/short title تحليل عددى لجودة الهواء الداخلى فى الصيدليات الاكلينيكية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Rana Essam Eldin Khalil Hassan Khalil ,
Date of publication, distribution, etc. 2016
300 ## - PHYSICAL DESCRIPTION
Extent 151 P. :
Other physical details photographs ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Engineering - Department of Mechanical Power Engineering
520 ## - SUMMARY, ETC.
Summary, etc. The present work describes and analyses the flow and heat transfer regimes inside clinical pharmacies through investigating a typical pharmacy. Five different design configurations of clinical pharmacies HVAC systems have been compared numerically to assess their agreement with international standards of clean room ventilation and airflow pattern requirements. It was concluded that the third configuration is the best in contaminant control. Numerical approach was utilized to adequately identify the airflow patterns, temperatures, relative humidity distributions and particle concentrations
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Clinical pharmacies
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Indoor air quality
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Numerical analysis
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Esmail Mohamed Ali Elbialy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Mahmoud Aly Hassan ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Samy Morad Morcos ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.11.Ph.D.2016.Ra.N 01010110072058000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.11.Ph.D.2016.Ra.N 01020110072058000 22.09.2023 CD - Rom 72058.CD