MARC details
000 -LEADER |
fixed length control field |
01889cam a2200325 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
170708s2016 ua o f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
Ph.D |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.13.11.Ph.D.2016.Ra.N |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Rana Essam Eldin Khalil Hassan Khalil |
245 10 - TITLE STATEMENT |
Title |
Numerical analysis of indoor air quality in clinical pharmacies / |
Statement of responsibility, etc. |
Rana Essam Eldin Khalil Hassan Khalil ; Supervised Samy M. Morcos , Mohamed Aly Hassan , Esmail M. Bialy |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
تحليل عددى لجودة الهواء الداخلى فى الصيدليات الاكلينيكية |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Rana Essam Eldin Khalil Hassan Khalil , |
Date of publication, distribution, etc. |
2016 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
151 P. : |
Other physical details |
photographs ; |
Dimensions |
30cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (Ph.D.) - Cairo University - Faculty of Engineering - Department of Mechanical Power Engineering |
520 ## - SUMMARY, ETC. |
Summary, etc. |
The present work describes and analyses the flow and heat transfer regimes inside clinical pharmacies through investigating a typical pharmacy. Five different design configurations of clinical pharmacies HVAC systems have been compared numerically to assess their agreement with international standards of clean room ventilation and airflow pattern requirements. It was concluded that the third configuration is the best in contaminant control. Numerical approach was utilized to adequately identify the airflow patterns, temperatures, relative humidity distributions and particle concentrations |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Clinical pharmacies |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Indoor air quality |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Numerical analysis |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Esmail Mohamed Ali Elbialy , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Mohamed Mahmoud Aly Hassan , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Samy Morad Morcos , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Samia |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |