Maintenance requirements of screw retained implant prosthesis versus telescopic overdenture : (Record no. 61529)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02848cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223031742.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 170711s2016 ua h f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | Ph.D |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.09.Ph.D.2016.Wa.M |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Wafaa Ibrahim Ibrahim |
245 10 - TITLE STATEMENT | |
Title | Maintenance requirements of screw retained implant prosthesis versus telescopic overdenture : |
Remainder of title | A randomized controlled trial / |
Statement of responsibility, etc. | Wafaa Ibrahim Ibrahim ; Supervised Amal Fathy Kaddah , Amr Hosny Elkadem |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | إحتياجات الصيانة لتركيبات الغرسات المثبتة بالبراغى فى مقابل تركيبات الأطقم المحمولة التلسكوبية : |
Remainder of title | تجربة سريرية للتحكم الجزافى |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Wafaa Ibrahim Ibrahim , |
Date of publication, distribution, etc. | 2016 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 134 P. : |
Other physical details | facsimiles ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics |
520 ## - SUMMARY, ETC. | |
Summary, etc. | The present study was carried out on 26 completely edentulous patients. An informed consent was obtained from each patient. Patients received either screw-retained restorations or telescopic overdentures which were supported on four maxillary and four mandibular implants. The patients were imaged using CBCT and the DICOM data were imported to computer software for virtual implant planning. The virtual surgical guide was sent for prototyping to construct a computer-guided stent and implants were installed with a flapless technique. A follow up protocol at the day of loading, 6 months, 12 months and 18 months was scheduled to assess maintenance requirements. During the 18 months follow-up period, prosthodontic complications for the telescopic overdentures and the screw-retained restorations were registered and calculated. Regarding the removable group the most common complications were screw loosening of the abutment and prosthetic teeth fracture. While screw loosening of the abutments and prosthesis, fractured acrylic resin, fracture of teeth and remake of the prosthesis occurred in the fixed group. The results of the study revealed that there was no significant difference between the fixed and the removable group. The total incidence of prosthetic complications recorded was 10 times in the removable group and 14 times in the fixed group with no significant difference between both groups |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Maintenance requirements |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Screw retained implant |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Telescopic overdenture |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Amal Fathy Kaddah , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Amr Hosny Elkadem , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Samia |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.09.Ph.D.2016.Wa.M | 01010110072087000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.09.Ph.D.2016.Wa.M | 01020110072087000 | 22.09.2023 | CD - Rom | 72087.CD |