header

Single versus two implants retained mandibular overdenture : (Record no. 62157)

MARC details
000 -LEADER
fixed length control field 02595cam a2200313 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170827s2016 ua o f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2016.Ra.S
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ramy Khalifa Elsaid Elashmawy
245 10 - TITLE STATEMENT
Title Single versus two implants retained mandibular overdenture :
Remainder of title Three-dimensional finite element analysis /
Statement of responsibility, etc. Ramy Khalifa Elsaid Elashmawy ; Supervised Maha Wagdy , Nouran Abdelnaby
246 15 - VARYING FORM OF TITLE
Title proper/short title مقارنة الغرس المفرد بغرستان لإستبقاء الطقم السفلى الفوقي :
Remainder of title دراسة تحليلية للأحمال
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ramy Khalifa Elsaid Elashmawy ,
Date of publication, distribution, etc. 2016
300 ## - PHYSICAL DESCRIPTION
Extent 94 P. :
Other physical details photographs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. A 3D finite element analysis study was carried out to evaluate the effect of implant number on stress distribution in peri-implant bone and mandibular overdenture retained by one or two implant. A three-dimensional model of mandible was constructed using data from the computed tomographic image obtained from an edentulous patient. Two models were constructed, one restored with single midline implant retained overdenture and the other restored with two interforaminal implants at canine region. All variables rather than implant number were standardized for all the models. The material properties for compact bone, spongy bone, titanium alloy and acrylic were identified. Two loading conditions were applied vertical loads and oblique load. The model was restrained at it inferior border to avoid total body displacement. The model was meshed and analyzed using a finite element iterative solving method for stress analysis. Under vertical and oblique loading, both models showed stresses in peri-implant bone comparable to each other with slightly increased stresses in single implant model. Under both vertical and oblique loading, the single implant model showed significant increased stresses in denture base near the midline around the attachment system compared to the two implant model
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Retained mandibular overdenture
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Single versus two implants
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Three-dimensional finite element analysis
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Maha Wagdy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Nouran Abdelnaby ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Enas
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2016.Ra.S 01010110072500000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2016.Ra.S 01020110072500000 22.09.2023 CD - Rom 72500.CD