header

Knee stability after anterior cruciate reconstruction usig hamstring tendons as an autograft : (Record no. 62298)

MARC details
000 -LEADER
fixed length control field 03171cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031805.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170912s2016 ua h f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.25.Ph.D.2016.Za.K
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Zaky Basuony Elsayed Khalifa
245 10 - TITLE STATEMENT
Title Knee stability after anterior cruciate reconstruction usig hamstring tendons as an autograft :
Remainder of title Comparison between press fit and interference screw fixation techniques /
Statement of responsibility, etc. Zaky Basuony Elsayed Khalifa ; Supervised Abdelaziz Elsingergy , Hisham Misbah , Hazem Ahmad Farouk
246 15 - VARYING FORM OF TITLE
Title proper/short title ثبات الركبة بعد عملية اعادة بناء الرباط الصليبى باستخدام الاوتار الخلفية للركبة كرقعة ذاتية :
Remainder of title دراسة مقارنة بين طريقة التثبيت بالمسامير التداخلية و طريقة التثبيت بطرقة حشر رقعة عظمية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Zaky Basuony Elsayed Khalifa ,
Date of publication, distribution, etc. 2016
300 ## - PHYSICAL DESCRIPTION
Extent 140 P. :
Other physical details facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Orthopedic Surgery
520 ## - SUMMARY, ETC.
Summary, etc. Background: press-fit fixation has been advocated to achieve tendon to bone healing Hypothesis: Fixation of hamstring tendon grafts with a press fit (PF) bone plug gives good knee stability compared with interference screw (IS) fixation. Study design: Prospective randomized controlled trial; level of evidence I. Methods: From April 2011 to September 2015, a prospective randomized controlled study was undertaken to compare between two types of fixation for ACL graft (PF) and (IS) technique used in ACL reconstruction using hamstring tendons. 100 patients were operated; graft was fixed in 50 knees using (IS) and the other 50 knees fixed by (PF) bone plug. The follow up at 1 week, 2 weeks, 6 weeks, 12 weeks, 6 months and yearly afterward. Assessment (subjective, objective and instrumental) was done at 6 months post operatively. Results: There is no any significant differences between both group in subjective and instrumental evaluation, but the (IS) is better in ADT as 92% rated as normal, while 72 only in (PF) group, but the (PF) is better in ROM 96% rated as normal to nearly normal while 86% in (IS), post-operative effusion where 98% rated normal to nearly normal in (PF) while 88% in (IS) and pivot test where 96% rated normal to nearly normal in (PF) while 78% in (IS). Conclusion: both (PF) and (IS) fixation techniques lead to high number of very good to good results after ACL reconstruction, the (PF) is better in some objective aspects in addition to be biological, economic, and least technique with bone loss
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term ACL reconstruction
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Interference screw
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Press fit
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Abdelaziz Elsingergy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hazem Ahmad Farouk ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hisham Misbah ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.25.Ph.D.2016.Za.K 01010110072631000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.25.Ph.D.2016.Za.K 01020110072631000 22.09.2023 CD - Rom 72631.CD