header

Numerical investigation of flow patterns and thermal comfort in an air-conditioned library / (Record no. 63757)

MARC details
000 -LEADER
fixed length control field 01969cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171202s2017 ua o f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.11.M.Sc.2017.Mo.N
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohammed Ammar Mohammed Saad
245 10 - TITLE STATEMENT
Title Numerical investigation of flow patterns and thermal comfort in an air-conditioned library /
Statement of responsibility, etc. Mohammed Ammar Mohammed Saad ; Supervised Essam E. Khalil Hassan Khalil , Taher Mohamed Aboudeif , Ahmed Mahmoud Abouzaid
246 15 - VARYING FORM OF TITLE
Title proper/short title دراسة عددية لأنماط السريان و الراحة الحرارية لمكتبة مكيفة الهواء
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mohammed Ammar Mohammed Saad ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 146 P. :
Other physical details photographs ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Mechanical Power Engineering
520 ## - SUMMARY, ETC.
Summary, etc. The present thesis is devoted to numerical investigation of the change in location supply-return air are studied to revealed the impact of changing the location on the overall comfort levels for people. The study is carried out using (CFD) simulation techniques as embedded in the commercially available CFD code (FLUENT 16). The CFD modelling techniques solved the continuity, momentum and energy conservation equations in addition to comfort parameters PMV and PPD based on Fanger{u2019}s model and RNG k-f model equations for turbulence closure . The results had shown the best case when the supply air from wall and extract air from ceiling
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term CFD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Indoor air quality
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Thermal comfort
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Mahmoud Abouzaid ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Essam Eldin Khalil Hassan Khalil ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Taher Mohamed Aboudeif ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.11.M.Sc.2017.Mo.N 01010110073620000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.11.M.Sc.2017.Mo.N 01020110073620000 22.09.2023 CD - Rom 73620.CD