header

Effect of electric potential difference (kilovoltage) on accuracy of maxillary and mandibular linear measurements of planmeca promax 3d mid® cone beam computed tomography machine : (Record no. 64004)

MARC details
000 -LEADER
fixed length control field 03421cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031856.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171212s2017 ua dho f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.05.M.Sc.2017.Ah.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ahmed Magdy Fouad Mohamed
245 10 - TITLE STATEMENT
Title Effect of electric potential difference (kilovoltage) on accuracy of maxillary and mandibular linear measurements of planmeca promax 3d mid® cone beam computed tomography machine :
Remainder of title Diagnostic accuracy study /
Statement of responsibility, etc. Ahmed Magdy Fouad Mohamed ; Supervised Mushira M. Dahaba , Ahmed M. Abdalsamad
246 15 - VARYING FORM OF TITLE
Title proper/short title للتصويرالمقطعي بالحاسوب مخروطي الشعاع PlanmecaPromax 3D MID® تأثير فرق الجهد الكهربي (كيلو فولت ) علي دقة القياسات الخطيه في الفك العلوى و السفلي لجهاز :
Remainder of title دراسة دقة تشخيصية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ahmed Magdy Fouad Mohamed ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 114 P. :
Other physical details charts , facsimiles , photographs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral (Radiology and Diagnosis)
520 ## - SUMMARY, ETC.
Summary, etc. Objectives:Assement of accuracy of maxillary and mandibular linear measurements using different electric potential (KVp) in comparison with real linear measurement . Methods: it was performed on twenty two human dry skulls with mandibles acquired from Anatomy Department, Faculty of Medicine, Cairo University, Qassr El EinyHospital, 14mm wax used to simulate soft tissue attenuation , The skulls attached to their mandiles were radiographed using PlanmecaProMax 3D Mid CBCT machine (Asentajankatu, Helsinki, Finland) in Oral and Maxillofacial Radiology Department at Faculty of Oral and Dental Medicine, Cairo University All skulls with their mandibles were radiographed using 8 mA, (Ø20cm x 17 cm) field of view (FOV) using stitching and resolution of 400 æm voxel at an exposure time of 27 seconds. For kilovoltage (kVp), each skull was scanned by 3 different settings 90, 80 and 60 kVp. Real measurements were performed using a digital caliper by two experienced radiologists two weeks interval between first and second readings, the results yielded was subjected to Intra- and inter-observer agreement was assessed using Intra-Class Correlation Coefficient (ICC).Bland-Altman plot (differences-vs-means plot) used to show the agreement between two quantitative measurements by studying the mean difference and constructing limits of agreement . Results: there was inter and inter observer reliability ranging from- ICC (0.998 to 0.999) -which was excellent and according to Bland-Altman statistical test there was excellent correlation between measurements at ( 90-80-60 KVp) and real measurements . Conclusion: Maxillary and mandibular linear measurements driven from CBCT images of PlanamecaPromax 3D Mid® machine using 60, 80, 90 kVp are accurate and reliable for all maxillofacial applications
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term CBCT
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Cone beam CT
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Electric potential
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed M. Abdalsamad ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mushira M. Dahaba ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.05.M.Sc.2017.Ah.E 01010110073769000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.05.M.Sc.2017.Ah.E 01020110073769000 22.09.2023 CD - Rom 73769.CD