Effect of electric potential difference (kilovoltage) on accuracy of maxillary and mandibular linear measurements of planmeca promax 3d mid® cone beam computed tomography machine : (Record no. 64004)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03421cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223031856.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 171212s2017 ua dho f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.05.M.Sc.2017.Ah.E |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Ahmed Magdy Fouad Mohamed |
245 10 - TITLE STATEMENT | |
Title | Effect of electric potential difference (kilovoltage) on accuracy of maxillary and mandibular linear measurements of planmeca promax 3d mid® cone beam computed tomography machine : |
Remainder of title | Diagnostic accuracy study / |
Statement of responsibility, etc. | Ahmed Magdy Fouad Mohamed ; Supervised Mushira M. Dahaba , Ahmed M. Abdalsamad |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | للتصويرالمقطعي بالحاسوب مخروطي الشعاع PlanmecaPromax 3D MID® تأثير فرق الجهد الكهربي (كيلو فولت ) علي دقة القياسات الخطيه في الفك العلوى و السفلي لجهاز : |
Remainder of title | دراسة دقة تشخيصية |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Ahmed Magdy Fouad Mohamed , |
Date of publication, distribution, etc. | 2017 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 114 P. : |
Other physical details | charts , facsimiles , photographs ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral (Radiology and Diagnosis) |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Objectives:Assement of accuracy of maxillary and mandibular linear measurements using different electric potential (KVp) in comparison with real linear measurement . Methods: it was performed on twenty two human dry skulls with mandibles acquired from Anatomy Department, Faculty of Medicine, Cairo University, Qassr El EinyHospital, 14mm wax used to simulate soft tissue attenuation , The skulls attached to their mandiles were radiographed using PlanmecaProMax 3D Mid CBCT machine (Asentajankatu, Helsinki, Finland) in Oral and Maxillofacial Radiology Department at Faculty of Oral and Dental Medicine, Cairo University All skulls with their mandibles were radiographed using 8 mA, (Ø20cm x 17 cm) field of view (FOV) using stitching and resolution of 400 æm voxel at an exposure time of 27 seconds. For kilovoltage (kVp), each skull was scanned by 3 different settings 90, 80 and 60 kVp. Real measurements were performed using a digital caliper by two experienced radiologists two weeks interval between first and second readings, the results yielded was subjected to Intra- and inter-observer agreement was assessed using Intra-Class Correlation Coefficient (ICC).Bland-Altman plot (differences-vs-means plot) used to show the agreement between two quantitative measurements by studying the mean difference and constructing limits of agreement . Results: there was inter and inter observer reliability ranging from- ICC (0.998 to 0.999) -which was excellent and according to Bland-Altman statistical test there was excellent correlation between measurements at ( 90-80-60 KVp) and real measurements . Conclusion: Maxillary and mandibular linear measurements driven from CBCT images of PlanamecaPromax 3D Mid® machine using 60, 80, 90 kVp are accurate and reliable for all maxillofacial applications |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | CBCT |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Cone beam CT |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Electric potential |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Ahmed M. Abdalsamad , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Mushira M. Dahaba , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Shimaa |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.05.M.Sc.2017.Ah.E | 01010110073769000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.05.M.Sc.2017.Ah.E | 01020110073769000 | 22.09.2023 | CD - Rom | 73769.CD |