header

Quality assessment of polysaccharide vaccines using instrumental methods of analysis / (Record no. 64312)

MARC details
000 -LEADER
fixed length control field 02785cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031906.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171230s2017 ua d f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.08.03.M.Sc.2017.As.Q
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Asmaa Ramadan Hussein
245 10 - TITLE STATEMENT
Title Quality assessment of polysaccharide vaccines using instrumental methods of analysis /
Statement of responsibility, etc. Asmaa Ramadan Hussein ; Supervised Mostafaa Abdelaty Shehata , Mamdouh Reda Rezk , Faten Abdelaziz Fathalla
246 15 - VARYING FORM OF TITLE
Title proper/short title تحديد جودة اللقاحات عديدة السكاريد باستخدام طرق التحليل الآلى
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Asmaa Ramadan Hussein ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 197 P. :
Other physical details charts ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Pharmacy - Department of Analytical Chemistry
520 ## - SUMMARY, ETC.
Summary, etc. Meningococcal meningitis is a serious infection of the meninges that affects the brain membrane. Neisseria meningitidis is a potential cause to large epidemics. Meningococcal polysaccharide vaccines are available in either bivalent (A and C) or tetravalent (A, C, Y and W135). In this work, many tests were carried out to ensure safety, efficacy and quality of meningococcal AC vaccine. This was achieved through qualitative and quantitative tests as follows; vaccine vial monitor (VVM) grade is a screening testing for validity of vaccine. Polysaccharide content test is a quantitative test to determine the quantity of each serogroup. In this work polysaccharide content of polysaccharide A (PSA) will take only one day instead of two days. Molecular size distribution (MSD) is a quantitative test for the stability. It was done by using one of three proposed methods (Individual fractions method, pooling method and ELISA method). The proposed chromatographic conditions save about 7.5 hours, compared with the official method. Pooling method is easier to handle, faster, simpler, less expensive, safe, more accurate, and applicable, because of two pools were used for testing instead of using a large numbers of individual fractions test tubes, its calculations were based on calibration curve and linear equation with more accurate results, it is saving the expensive reference and reagents used in the analysis
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Instrumental method
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Instrumental methods of analysis
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Polysaccharide vaccines
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Faten Abdelaziz Fathalla ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mamdouh Reda Rezk ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mostafaa Abdelaty Shehata ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.08.03.M.Sc.2017.As.Q 01010110073951000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.08.03.M.Sc.2017.As.Q 01020110073951000 22.09.2023 CD - Rom 73951.CD