Scattered radiation effects on the performance of diagnostic nuclear medicine devices / (Record no. 64362)

MARC details
000 -LEADER
fixed length control field 02769cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031908.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180101s2017 ua ho f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.12.04.Ph.D.2017.Mo.S
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohamed Abdelnaby Abdelazeem Ghoneim
245 10 - TITLE STATEMENT
Title Scattered radiation effects on the performance of diagnostic nuclear medicine devices /
Statement of responsibility, etc. Mohamed Abdelnaby Abdelazeem Ghoneim ; Supervised Wael M. Elshemey , Mahmoud H. Khedr
246 15 - VARYING FORM OF TITLE
Title proper/short title تأثير الإشعاع المشتت على آداء أجهزة الطب النووى التشخيصية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mohamed Abdelnaby Abdelazeem Ghoneim ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 106 P. :
Other physical details facsimiles , photographs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Science - Department of Biophysics
520 ## - SUMMARY, ETC.
Summary, etc. This work employs a point source to investigate the effects of phantom thickness and source-to-detector distance on the extrinsic sensitivity and counting efficiency of a gamma camera with a rectangular detector. Measurements are performed using 99mTc source (0.197±3.7{u00D7}10-4 GBq) and a water phantom container (as a scattering medium). The scatter fraction is determined through the analysis of the energy spectra of 99mTc for a certain energy window. Results show the direct dependence of the calculated extrinsic counting efficiency on the solid angle subtended by a point source on a rectangular detector. The increase in water thickness from 0.0 to 200 mm resulted in an increase in the scatter fraction from 0.20 to 24.12. This increase is also associated with a decrease in the extrinsic sensitivity from 121.59 to 11.15 counts/s.GBq, and a decrease in extrinsic counting efficiency from 0.039 to 0.0036%. The increase in source-to-detector distance from 0.50 to 1.10 m is accompanied by a decrease in extrinsic sensitivity from 121.59 to 115.53 counts/s.GBq and an increase in extrinsic counting efficiency from 0.039 to 0.15%. In such point source geometry, it is found that a source-to-detector distance of 0.79±0.02 m is a good compromise for an acceptable extrinsic sensitivity and a reasonable extrinsic counting efficiency. Some important differences between the present results and published measurements using a flood source are extensively discussed
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Extrinsic counting efficiency
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Gamma camera
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Scattered fraction
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mahmoud H. Khedr ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Wael M. Elshemey ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.12.04.Ph.D.2017.Mo.S 01010110074038000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.12.04.Ph.D.2017.Mo.S 01020110074038000 22.09.2023 CD - Rom 74038.CD