header

Accuracy of planmeca promax 3D MID® cone beam computed tomography machine in mandibular linear measurements : (Record no. 64487)

MARC details
000 -LEADER
fixed length control field 03143cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031912.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180109s2017 ua o f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.05.M.Sc.2017.Ab.A
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Abdelrahman Ali Gamal Eldin Abdelrahman
245 10 - TITLE STATEMENT
Title Accuracy of planmeca promax 3D MID® cone beam computed tomography machine in mandibular linear measurements :
Remainder of title A diagnostic accuracy study /
Statement of responsibility, etc. Abdelrahman Ali Gamal Eldin Abdelrahman ; Supervised Nashwa Salah , Ahmed M. Abdalsamad
246 15 - VARYING FORM OF TITLE
Title proper/short title للتصويرالمقطعى بالحاسوب مخروطى الشعاع فى القياسات الخطية للفك السفلى Planmeca Promax 3d Mid دقة جهاز :
Remainder of title دراسة دقة تشخيصية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Abdelrahman Ali Gamal Eldin Abdelrahman ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 104 P. :
Other physical details photographs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Ora (Radiology and Diagnosis)
520 ## - SUMMARY, ETC.
Summary, etc. Objectives: Assessment of accuracy and reliability of planmeca promax 3D MID® CBCT machine as an imaging modality in mandibular linear measurements compared with real linear measurement. Methods: The study is a cross sectional prospective study performed on 30 dry mandibles obtained from the anatomy department of Faculty of medicine, Cairo university. For each mandible, three sites were selected .In each site, two measurements were measured using a digital caliper. Gutta-percha markers were glued on the marked areas labially/buccally and lingually to serve as reference points in the software measurements after CBCT imaging. The Mandibles were scanned using planmeca proMax 3D Mid CBCT machine using 90 kVp, 8 m A, (Ø20cm x10 cm) field of view (FOV), and resolution of 400 æm voxel at an exposure time of 13.5 seconds. Measurements were done by two blinded radiologists independently in 2 different sessions. The results yielded was subjected to Intra- and inter-observer agreement was assessed using intra-class correlation coefficient (ICC). Bland-altman plot (differences-vs-means plot) is used to test the agreement between two quantitative measurements by studying the mean difference and constructing limits of agreement. Results: There was excellent correlation between measurements obtained from CBCT images of olanameca oromax 3D Mid® machine and real measurements in both vertical and horizontal direction. There was excellent inter and inter observer reliability. Conclusion: Mandibular linear measurements driven from CBCT images of planameca promax 3D Mid® machine are accurate, reproducible and reliable in both the horizontal and vertical directions
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term 3D MID®
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term CBCT
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Mandibular linear measurements
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Mohamed Abdalsamad ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Nashwa Salah ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.05.M.Sc.2017.Ab.A 01010110074074000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.05.M.Sc.2017.Ab.A 01020110074074000 22.09.2023 CD - Rom 74074.CD