Accuracy of planmeca promax 3D MID® cone beam computed tomography machine in mandibular linear measurements : (Record no. 64487)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03143cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223031912.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 180109s2017 ua o f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.05.M.Sc.2017.Ab.A |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Abdelrahman Ali Gamal Eldin Abdelrahman |
245 10 - TITLE STATEMENT | |
Title | Accuracy of planmeca promax 3D MID® cone beam computed tomography machine in mandibular linear measurements : |
Remainder of title | A diagnostic accuracy study / |
Statement of responsibility, etc. | Abdelrahman Ali Gamal Eldin Abdelrahman ; Supervised Nashwa Salah , Ahmed M. Abdalsamad |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | للتصويرالمقطعى بالحاسوب مخروطى الشعاع فى القياسات الخطية للفك السفلى Planmeca Promax 3d Mid دقة جهاز : |
Remainder of title | دراسة دقة تشخيصية |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Abdelrahman Ali Gamal Eldin Abdelrahman , |
Date of publication, distribution, etc. | 2017 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 104 P. : |
Other physical details | photographs ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Ora (Radiology and Diagnosis) |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Objectives: Assessment of accuracy and reliability of planmeca promax 3D MID® CBCT machine as an imaging modality in mandibular linear measurements compared with real linear measurement. Methods: The study is a cross sectional prospective study performed on 30 dry mandibles obtained from the anatomy department of Faculty of medicine, Cairo university. For each mandible, three sites were selected .In each site, two measurements were measured using a digital caliper. Gutta-percha markers were glued on the marked areas labially/buccally and lingually to serve as reference points in the software measurements after CBCT imaging. The Mandibles were scanned using planmeca proMax 3D Mid CBCT machine using 90 kVp, 8 m A, (Ø20cm x10 cm) field of view (FOV), and resolution of 400 æm voxel at an exposure time of 13.5 seconds. Measurements were done by two blinded radiologists independently in 2 different sessions. The results yielded was subjected to Intra- and inter-observer agreement was assessed using intra-class correlation coefficient (ICC). Bland-altman plot (differences-vs-means plot) is used to test the agreement between two quantitative measurements by studying the mean difference and constructing limits of agreement. Results: There was excellent correlation between measurements obtained from CBCT images of olanameca oromax 3D Mid® machine and real measurements in both vertical and horizontal direction. There was excellent inter and inter observer reliability. Conclusion: Mandibular linear measurements driven from CBCT images of planameca promax 3D Mid® machine are accurate, reproducible and reliable in both the horizontal and vertical directions |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | 3D MID® |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | CBCT |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Mandibular linear measurements |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Ahmed Mohamed Abdalsamad , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Nashwa Salah , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Samia |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.05.M.Sc.2017.Ab.A | 01010110074074000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.05.M.Sc.2017.Ab.A | 01020110074074000 | 22.09.2023 | CD - Rom | 74074.CD |