Accuracy of transcutaneous bilirubinometry compared to total serum bilirubin measurement by laboratory method in neonatal jaundice / (Record no. 64780)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03222cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223031922.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 180201s2017 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.11.28.M.Sc.2017.Ni.A |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Nirmeen Samaan Barsoum Gaid |
245 10 - TITLE STATEMENT | |
Title | Accuracy of transcutaneous bilirubinometry compared to total serum bilirubin measurement by laboratory method in neonatal jaundice / |
Statement of responsibility, etc. | Nirmeen Samaan Barsoum Gaid ; Supervised Magda Mahmoud Sedky Badawy , Dalia Sayed Mosallam |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | دقة قياس نسبة البيليروبين عبر الجلد باستخدام الجهاز بالمقارنة مع قياس نسبة البيليروبين الكلى بالدم استخدام المختبر فى الأطفال المبتسرين و حديثى الولادة |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Nirmeen Samaan Barsoum Gaid , |
Date of publication, distribution, etc. | 2017 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 144 P. : |
Other physical details | charts , facsimiles ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Pediatrics |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Backround: Routine use of transcutaneous bilirubin (TcB) measurement in the newborn nursery could reduce costs, readmission rates for hyperbilirubinemia and the need for total serum bilirubin (TSB) measurements. Objectives: To compare transcutaneous and plasma bilirubin measurements before, during and after phototerapy, on sternum (exposed), forehead and back (covered) areas, to verify the correlation between TSB and TcB levels in full term and preterm infants to use it as screening method for neonatal jaundice. Methods: A prospective cohort study was performed on 200 neonates with indirect hyperbilirubinemia, Simultaneous plasmatic and transcutaneous (frontal, sternal and back regions) (within 30 min) bilirubin assays were performed before, 12 hours after the beginning of phototerapy and 6 hrs after discontinuing photo. The association between the measurements and neonatal weight, sex, gestational and postnatal ages and the type of photo was calculated Results: we studied 169 terms and 31 preterms. TSB and TcB measurements of Pre-phototherapy, at 12 hours after the beginning of phototerapy and at 6 hrs after discontinuing photo, showed that there were strong correlations between TSB & TcB regardless to timing and site of measurements. No neonatal characteristics were significantly affected transcutaneous bilirubin measurements. Conclusion: Transcutneous bilirubinometry has demonstrated signi{uFB01}cant accuracy compared to TSB, so can be safely used for evaluation of bilirubin level in preterm and term infants, but take inconsideration pre-phototherapy more accurate over sternum and back, while during and after photo more accurate over covered areas (forehead and back) |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Hyperbilirubinemia |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Neonatal jaundice |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Transcutneous bilirubinometry |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Dalia Sayed Mosallam , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Magda Mahmoud Sedky Badawy , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Shimaa |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.11.28.M.Sc.2017.Ni.A | 01010110074220000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.11.28.M.Sc.2017.Ni.A | 01020110074220000 | 22.09.2023 | CD - Rom | 74220.CD |