header

Comparative study between the new 3-D iterative reconstruction algorithm and the standard reconstruction algorithm in Gated SPECT myocardial perfusion imaging / (Record no. 65358)

MARC details
000 -LEADER
fixed length control field 03736cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031941.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180310s2017 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.12.04.M.Sc.2017.Yo.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Youssef Rabie Ahmed
245 10 - TITLE STATEMENT
Title Comparative study between the new 3-D iterative reconstruction algorithm and the standard reconstruction algorithm in Gated SPECT myocardial perfusion imaging /
Statement of responsibility, etc. Youssef Rabie Ahmed ; Supervised Ahmed Sultan , Alia Abdelfattah , Shaaban Abdelhamid
246 15 - VARYING FORM OF TITLE
Title proper/short title المقارنه بين الطزق اللوغارتمية التكرارية ثلاثيه الأبعاد والطرق القياسية في تصوير المسح الذرى علي عضلة القلب
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Youssef Rabie Ahmed ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 77 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of science - Department of Biophysics
520 ## - SUMMARY, ETC.
Summary, etc. Background: Myocardial perfusion imaging (MPI) using 99mTc-labeled sesta MIBI is used in various clinical settings to provide invaluable information about coronary artery disease. Image reconstruction algorithm such as filtered-back-projection (FBP) and iterative reconstructions (2D and 3D) with resolution recovery are playing a pivotal role in image quality evaluation of (MPI). Aims: The aim of the present study was to provide a comparative analysis among the three reconstruction algorithms FBP, 2D ordered subset expectation maximization (2D-OSEM) and 3D-OSEM (Flash-3D) with resolution recovery provided by system manufacturer in evaluating image quality of gated MPI Materials and Methods: The patient population was divided into three groups such that the first group (gp1) received the full standard dose and scanned using the adopted acquisition protocol routinely used in our clinic (32 views, 20 sec/view, 64x64 matrix size, using 925 MBq administered activity), group 2 (gp2) in which the acquisition protocol was reduced to 16 views using 20 sec/view, matrix size of 64x64 with injected activity of 925 MBq and the last group (gp3) was examined using the same imaging protocol like group 1 but with half dose (i.e. 444 MBq). All patients acquired data were processed using FBP (Butterworth filter: cut-off=0.5, order=5), OSEM-2D (8 subsets, 12 iterations, FWHM=11 mm) and Flash-3D iterative algorithms (8 subsets, 12 iterations, FWHM=11 mm). Quality of the reconstructed data were evaluated in terms of image contrast, relative noise level as well as contrast to noise ratio. Results: in terms of image noise, Flash-3D reconstruction algorithm increased the image noise (P>0.05) as compared with FBP and OSEM-2D. Also, OSEM-2D iterative algorithm increased the image noise (P>0.05) as compared with FBP. Flash-3D reconstruction algorithm significantly increased the image contrast (P<0.05) as compared with FBP and OSEM-2D. Also, OSEM-2D iterative algorithm significantly increased the image contrast (P<0.05) as compared with FBP. Flash 3D reconstruction algorithm reduced the image CNR by 13.3% (P=NS) than FBP and 4.82% (P=NS) than OSEM2-D respectively. Also, the OSEM-2D reconstruction algorithm decreased the image CNR by 8.1% (P = NS) than FBP
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term 3-D iterative
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term 3-D iterative reconstruction algorithm
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term SPECT
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Sultan ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Alia Abdelfattah ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Shaaban Abdelhamid ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.12.04.M.Sc.2017.Yo.C 01010110074557000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.12.04.M.Sc.2017.Yo.C 01020110074557000 22.09.2023 CD - Rom 74557.CD