header

Detection and characterization of different breast masses Comparative study between automated breast 3D ultrasound and 3D tomosynthesis / (Record no. 65383)

MARC details
000 -LEADER
fixed length control field 02421cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031941.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180311s2017 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.31.M.Sc.2017.Re.D
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Reham Hussein Mohamed Ali
245 10 - TITLE STATEMENT
Title Detection and characterization of different breast masses Comparative study between automated breast 3D ultrasound and 3D tomosynthesis /
Statement of responsibility, etc. Reham Hussein Mohamed Ali ; supervised Maha Hussein Helal , Emad Eldin Egemeae , Lamiaa Mohamed Bassam Fayek Mohamed Hashem
246 15 - VARYING FORM OF TITLE
Title proper/short title دراسة مقارنة بين الموجات فوق الصوتية ( ثلاثية الابعاد ) والأشعة البنائية المقطعية ( ثلاثية الابعاد ) فى إيجاد وتميز اورام الثدى المختلفة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Reham Hussein Mohamed Ali ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 140 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Radio-diagnosis
520 ## - SUMMARY, ETC.
Summary, etc. Breast cancer is the most common invasive cancer to affect women in the world. It is the second highest cause of cancer death in women after lung cancer. Breast cancer screening remains a subject of intense debate. Mammography has long been the mainstay of breast cancer detection and is the only screening test proven to reduce mortality. Although it remains the gold standard of breast cancer screening, there is increasing awareness of subpopulations of women for whom mammography has reduced sensitivity. Mammography also has undergone increased critical observation for false positives and excessive biopsies, which increase radiation dose, cost, and patient anxiety. In response to these challenges, new technologies for breast cancer screening have been developed, including tomosynthesis, automated whole breast ultrasound
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term 3D tomosynthesis
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Automated breast 3D ultrasound
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Characterization
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Emad Eldin Elgemeae ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Lamiaa Mohamed Bassam Fayek Mohamed Hashem ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Maha Hussein Helal ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.31.M.Sc.2017.Re.D 01010110074568000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.31.M.Sc.2017.Re.D 01020110074568000 22.09.2023 CD - Rom 74568.CD