header

The effect of different abutment materials on the fracture resistance and stress distribution of implant supported fixed partial denture : (Record no. 65464)

MARC details
000 -LEADER
fixed length control field 03172cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031944.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180317s2017 ua do f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.Ph.D.2017.Mo.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohamed Mostafa Mohamed
245 14 - TITLE STATEMENT
Title The effect of different abutment materials on the fracture resistance and stress distribution of implant supported fixed partial denture :
Remainder of title In vitro study = تأثير اختلاف المواد الداعمة للبنية الفوقية المرممة للغرسة على مقاومة الكسر و توزيع الضغط : دراسة فى المختبر /
Statement of responsibility, etc. Mohamed Mostafa Mohamed ; Supervised Omaima Elmahallawi , Gihan Elnagar
246 15 - VARYING FORM OF TITLE
Title proper/short title تأثير اختلاف المواد الداعمة للبنية الفوقية المرممة للغرسة على مقاومة الكسر و توزيع الضغط :
Remainder of title دراسة فى المختبر
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mohamed Mostafa Mohamed ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 144 P. :
Other physical details charts , photographs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. Successful long-term results of dental implants have led to an increase in their usage in many clinical situations. Since the introduction of osseo-integrated implants for the rehabilitation of the partially edentulous patient, a tremendous awareness and subsequent demand have arisen in the field resulting in implant supported fixed prosthesis being widely accepted as an alternative to conventional removable prosthesis. However, some clinical studies have reported variable rates of failure. Biomechanical factors and stress distribution around implant supported FPDs are some of the prime factors leading to failure of implant supported. The current study evaluated the effect of different abutment materials titanium and zirconia with different bone density (D2 and D3) on the stress distribution and fracture resistance of implant supported FPD. The relative effect of the two different abutment materials were compared using mechanical loading test together with strain gauge analysis. The following materials were used in the current study: 1. Zimmer dental Implant fixture. 2. Zimmer dental implant abutment.(titanium and zirconia) 3. in Coris TZI medi block 4. Provicol C temporary cement. 5. Unsaturated epoxy resin (cancellous bone). 6. Saturated epoxy resin (compact bone). Summary and conclusion 7. Electrical resistance strain gauges. Eight implants were fixed in four anatomically correct D2 and D3 bone density models in order to stimulate restoring posterior missing second premolar, first molar and second molar
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Different abutment materials
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Fracture resistance
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Stress distribution
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Gihan Elnagar ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Omaima Elmahallawi ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.Ph.D.2017.Mo.E 01010110074601000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.Ph.D.2017.Mo.E 01020110074601000 22.09.2023 CD - Rom 74601.CD