The effect of different abutment materials on the fracture resistance and stress distribution of implant supported fixed partial denture : (Record no. 65464)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03172cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223031944.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 180317s2017 ua do f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | Ph.D |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.09.Ph.D.2017.Mo.E |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Mohamed Mostafa Mohamed |
245 14 - TITLE STATEMENT | |
Title | The effect of different abutment materials on the fracture resistance and stress distribution of implant supported fixed partial denture : |
Remainder of title | In vitro study = تأثير اختلاف المواد الداعمة للبنية الفوقية المرممة للغرسة على مقاومة الكسر و توزيع الضغط : دراسة فى المختبر / |
Statement of responsibility, etc. | Mohamed Mostafa Mohamed ; Supervised Omaima Elmahallawi , Gihan Elnagar |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | تأثير اختلاف المواد الداعمة للبنية الفوقية المرممة للغرسة على مقاومة الكسر و توزيع الضغط : |
Remainder of title | دراسة فى المختبر |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Mohamed Mostafa Mohamed , |
Date of publication, distribution, etc. | 2017 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 144 P. : |
Other physical details | charts , photographs ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Successful long-term results of dental implants have led to an increase in their usage in many clinical situations. Since the introduction of osseo-integrated implants for the rehabilitation of the partially edentulous patient, a tremendous awareness and subsequent demand have arisen in the field resulting in implant supported fixed prosthesis being widely accepted as an alternative to conventional removable prosthesis. However, some clinical studies have reported variable rates of failure. Biomechanical factors and stress distribution around implant supported FPDs are some of the prime factors leading to failure of implant supported. The current study evaluated the effect of different abutment materials titanium and zirconia with different bone density (D2 and D3) on the stress distribution and fracture resistance of implant supported FPD. The relative effect of the two different abutment materials were compared using mechanical loading test together with strain gauge analysis. The following materials were used in the current study: 1. Zimmer dental Implant fixture. 2. Zimmer dental implant abutment.(titanium and zirconia) 3. in Coris TZI medi block 4. Provicol C temporary cement. 5. Unsaturated epoxy resin (cancellous bone). 6. Saturated epoxy resin (compact bone). Summary and conclusion 7. Electrical resistance strain gauges. Eight implants were fixed in four anatomically correct D2 and D3 bone density models in order to stimulate restoring posterior missing second premolar, first molar and second molar |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Different abutment materials |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Fracture resistance |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Stress distribution |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Gihan Elnagar , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Omaima Elmahallawi , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Samia |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.09.Ph.D.2017.Mo.E | 01010110074601000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.09.Ph.D.2017.Mo.E | 01020110074601000 | 22.09.2023 | CD - Rom | 74601.CD |