header

Evaluation of shear bond strength of Fuji IX and Riva with and without salivary contamination on deciduous molars : (Record no. 65471)

MARC details
000 -LEADER
fixed length control field 03710cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031944.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180318s2016 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.07.M.Sc.2016.Ha.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Hazim Fawzy Elmoabayed
245 10 - TITLE STATEMENT
Title Evaluation of shear bond strength of Fuji IX and Riva with and without salivary contamination on deciduous molars :
Remainder of title An in- vitro study /
Statement of responsibility, etc. Hazim Fawzy Elmoabayed ; Supervised Sherif Bahget , Rania Abdullah
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم قوة رابطة القص في الريفا و الفوجي 9 مع و بدون التلوث اللعابي علي الضروس اللبنية:
Remainder of title دراسة معملية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Hazim Fawzy Elmoabayed ,
Date of publication, distribution, etc. 2016
300 ## - PHYSICAL DESCRIPTION
Extent 78 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Pedodontics
520 ## - SUMMARY, ETC.
Summary, etc. This study was performed to evaluate the shear bond strengths of GC Fuji IX GP and Riva resin modified glass ionomer as a filling material of deciduous molars with and without salivary contamination by using instron universal testing Machine (an in-vitro study).Shear bond strength of investigating materials to middle of the dentin of primary molars after 24 hours. A totalone hundred and forty tooth caries free freshly extracted or sheded second primary molars were utilized in this study. The tooth was divided into two main groups according to material used in which the group I GC Fuji IX GP (n = 60) and divided into three subgroups, each group contain twenty primary molars with and without salivary contamination while group II Riva SDI (n= 80) in which divided into four subgroups each group contain twenty primary molars with and without salivary contamination.Theocclusal surface of molars was grounded by diamond disc into the flat dentin surface, which materials were applied according to their manufacture's instructions Fuji IX and Riva glass ionomers was applied in pediatric catheter sections (1 inch in diameter and 1 inch in hight) were constructed on the occlusal surface of specimens.In the salivary contaminated subgroups, the dentinal surface was contaminated with human saliva by using a dropper,After 1 minute, the saliva was blotted drywith tissue paper, the mixed filling was placed on the dentin surface with a gentle pressure by using the applier to which shear force was applied to a failure using a universal testing machine at a crosshead speed of 0.5 mm/minute. The results of the present studyin the group I GC Fuji IX GP, It found the Fuji IX regular without saliva contamination recorded statistically significant (P<0.05) the heighest shear bond strength mean value (3.32 ± 0.51 MPa) while Fuji IX fast with saliva contamination recorded statistically significant (P<0.05) the heighest shear bond strength mean value (3.35 ± 0.45 MPa) , on other hand, in the groupIIRiva SDI , It found the riva light cure regular without saliva contamination recorded statistically significant (P<0.05) the highest shear bond strength mean value (8.173 ± 2.7 MPa), also, with sailiva contamination recorded statistically significant (P<0.05) the highest shear bond strength mean value (7.03 ± 1.7 MPa)
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Bond strength
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Glass-ionomers
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Salivary contamination
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Rania Abdullah ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Sherif Bahget ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.07.M.Sc.2016.Ha.E 01010110074635000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.07.M.Sc.2016.Ha.E 01020110074635000 22.09.2023 CD - Rom 74635.CD