header

The value of prone SPECT versus SPECT/CT in attenuation correction of myocardial perfusion imaging / (Record no. 65582)

MARC details
000 -LEADER
fixed length control field 03128cam a2200361 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031947.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180325s2017 ua h f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.22.M.Sc.2017.Ra.V
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Rana Emam Abdelbary Elashmawy
245 14 - TITLE STATEMENT
Title The value of prone SPECT versus SPECT/CT in attenuation correction of myocardial perfusion imaging /
Statement of responsibility, etc. Rana Emam Abdelbary Elashmawy ; Supervised Mahassen Amin Abogabal , Yasser Mohamed Elsayed , Ahmed Essam Eldein Tawakol
246 15 - VARYING FORM OF TITLE
Title proper/short title تصوير وضعية الاستلقاء على الوجه بالماسح الذري أحادي الفوتون مقابل دور الماسح الذري أحادي الفوتون المدمج بالأشعة المقطعية فى تصحيح الانحراف في تصوير التروية الدموية لعضلة القلب
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Rana Emam Abdelbary Elashmawy ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 85 P. :
Other physical details charts , fcsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Nuclear Medicine
520 ## - SUMMARY, ETC.
Summary, etc. The main objective of the study is to evaluate the role of prone images in attenuation correction and compare it to CT attenuation correction in myocardial perfusion imaging (MPI). Forty seven patients were initially included in the study. Statistical analysis was done for thirty patients with suspected or confirmed ischemic heart disease (IHD). All the patients underwent the ordinary supine stress/rest SPECT myocardial perfusion imaging (MPI) then; additional stress/rest prone SPECT as well as stress/rest SPECT/CT images were acquired, each study was interpreted separately and their results were compared. It was found that 58% (31/53) of the depicted defects were attributed to attenuation artifacts; the CT_AC imaging technique was able to correct 52.8% versus 49% for prone imaging. Our results showed that CT_AC technique is slightly better than prone imaging however, the results are still comparable. Also, CT-AC as well as the prone imaging increased the specificity and diagnostic accuracy of myocardial perfusion imaging, however the sensitivity is not affected, the sensitivity, specificity and diagnostic accuracy were 100%, 90.3% and 94.3% for CT_AC respectively versus 100%, 83.8% and 91% for prone imaging. Inferior wall defects were more common in males (95%) and anterior wall defects were more common in females (83.3%). In conclusion, both CT and prone imaging increased the specificity and diagnostic accuracy of myocardial perfusion imaging without affecting the sensitivity
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Myocardial perfusion imaging
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term SPECT
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term SPECT/CT
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Essam Eldein Tawakol ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mahassen Amin Abogabal ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Yasser Mohamed Elsayed ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
No. of Items 2
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Copy number Koha item type
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.22.M.Sc.2017.Ra.V 01010110074703000 22.09.2023 C.2 Thesis
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.22.M.Sc.2017.Ra.V 01010110074682000 22.09.2023   Thesis
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.22.M.Sc.2017.Ra.V 01020110074682000 22.09.2023 74682.CD CD - Rom
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.22.M.Sc.2017.Ra.V 01020110074703000 22.09.2023 74703.CD | C.2 CD - Rom