header

Retropupillary fixation of iris-claw intraocular lens versus transscleral sutureless fixation of intraocular lens for aphakic eyes without capsular support / (Record no. 65658)

MARC details
000 -LEADER
fixed length control field 02831cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180331s2017 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.24.Ph.D.2017.As.R
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Asmaa Mahmoud Shuaib
245 10 - TITLE STATEMENT
Title Retropupillary fixation of iris-claw intraocular lens versus transscleral sutureless fixation of intraocular lens for aphakic eyes without capsular support /
Statement of responsibility, etc. Asmaa Mahmoud Shuaib ; Supervised Hala Al Hilaly , Ahmed Mostafa Kamal , Yasmine Mohammed Elsayed
246 15 - VARYING FORM OF TITLE
Title proper/short title دراسة مقارنة بين تثبيت عدسة المخلب القزحي خلف الحدقة و تثبيت العدسة الخلفية عبر الصلبة بدون خيوط جراحية لحالات اللاعدسية مع عدم وجود المحفظة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Asmaa Mahmoud Shuaib ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 140 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Ophthalmology
520 ## - SUMMARY, ETC.
Summary, etc. The iris-fixated lenses include the iris-claw lens and iris sutured posterior chamber lenses which are fixated to the midperipheral iris. The iris-claw lens can be fixated either in the anterior chamber or retropupillary. (De Silva SR et al., 2011) The anterior chamber iris-claw lens has the risk of endothelial cell loss. (Kim M et al., 2008) So, retropupillary fixation of iris-claw lens is considered to be of better cosmetic benefit and lower effect on corneal endothelium. (Kohnen T et al., 2010) Because of its anatomic location, the scleral fixated PCIOL is more appropriate for eyes with compromised cornea, peripheral anterior synechiae, shallow anterior chamber, deficient iris tissue, glaucoma and in young patients who have a life expectancy of 10 years or more. (Dick HB & Augustin AJ., 2001) However, the scleral-fixated PCIOLs have complica»tions such as late IOL dislocation, due to suture degradation (Price MO et al., 2005). So, IOL implantation by sutureless transscleral fixation has gained popularity to avoid these complications and provide more stability. (Kumar DA, 2012) To our knowledge, the two surgical techniques of retropupillary iris-claw lens implantation and PCIOL transscleral sutureless fixation were not compared in pediatric age group to date
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Aphakic eyes without capsular support
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Iris sutured posterior chamber lenses
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term The iris-fixated lenses include the iris-claw lens
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Mostafa Kamal ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hala Al Hilaly ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Yasmine Mohammed Elsayed ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.24.Ph.D.2017.As.R 01010110074718000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.24.Ph.D.2017.As.R 01020110074718000 22.09.2023 CD - Rom 74718.CD