header

Numerical investigation on effect of fire fighting on smoke movement in tunnels / (Record no. 66013)

MARC details
000 -LEADER
fixed length control field 02114cam a2200313 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180428s2017 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.11.M.Sc.2017.Ra.N
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ramy Mahmoud Ragab Mahmoud
245 10 - TITLE STATEMENT
Title Numerical investigation on effect of fire fighting on smoke movement in tunnels /
Statement of responsibility, etc. Ramy Mahmoud Ragab Mahmoud ; Supervised Mahmoud Ahmed Fouad , Taher Mohamed Halawa
246 15 - VARYING FORM OF TITLE
Title proper/short title دراسة عددية لتأثير نظام الإطفاء على التحكم فى الدخان داخل الانفاق
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ramy Mahmoud Ragab Mahmoud ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 109 P. :
Other physical details charts , facsimiles ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Mechanical Power Engineering
520 ## - SUMMARY, ETC.
Summary, etc. Smoke is the most deadly factor in vehicular tunnels fire since smoke spreads in heading harmonize with passenger{u2019}s evacuation way. It reduces visibility and can cause fatalities by suffocation. This research presents a numerical study of the effect of extracting the smoke by different system of ventilation on smoke spread inside the vehicular tunnel, like (water mist system with transverse ventilation and longitudinal system with jet fans and solid curtain with transverse system and semi transverse system) Also tenable conditions were checked at human level. FDS 6.5.1 ver. was used to predict the various parameters of temperature, and visibility and Co concentration. Eight cases were conducted; Cases 1, 2, 3 and 7 were done to compare between four different ventilation systems at 30 MW. Case 4, 5, 6 and 8 were done to compare between three different ventilation systems at 100 MW
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Smoke management
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Vehicular tunnels
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Ventilation
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mahmoud Ahmed Fouad ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Taher Mohamed Halawa ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.11.M.Sc.2017.Ra.N 01010110074962000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.11.M.Sc.2017.Ra.N 01020110074962000 22.09.2023 CD - Rom 74962.CD