header

Numerical investigation for smoke mangement system in a closedindoor arena / (Record no. 66015)

MARC details
000 -LEADER
fixed length control field 01872cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032000.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180428s2017 ua h f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.11.M.Sc.2017.Ah.N
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ahmed Hassan Abdaleam Elsayed
245 10 - TITLE STATEMENT
Title Numerical investigation for smoke mangement system in a closedindoor arena /
Statement of responsibility, etc. Ahmed Hassan Abdaleam Elsayed ; Supervised Essam E. Khalil , Mohamed Ali Hassan , Ahmed Eldegawy
246 15 - VARYING FORM OF TITLE
Title proper/short title دراسة عددية لنظام التحكم فى الدخان داخل استاد رياضى مغلق
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ahmed Hassan Abdaleam Elsayed ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 112 P. :
Other physical details facsimiles ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Mechanical Power Engineering
520 ## - SUMMARY, ETC.
Summary, etc. Smoke management system is the most important parameter in the design of modern buildings. As smoke is toxic so it has a deadly effect on occupants. This research studies the effect of change heat release rate (HRR) in case of natural ventilation system on CO concentrations, temperature, smoke layer height and visibility at different locations in a closed indoor arena. The effect of using mechanical ventilation system with different (ACH) and the effect of change fire locations on the previous parameters was also studied
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Fire
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Fire dynamic simulator
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Smoke
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Eldegawy Ahmed Eldegawy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Essam Eldin Khalil Hassan Khalil ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Mahmoud Ali Hassan ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.11.M.Sc.2017.Ah.N 01010110074963000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.11.M.Sc.2017.Ah.N 01020110074963000 22.09.2023 CD - Rom 74963.CD