header

Parametric study of double pipe heat exchangers with internal wavy tape inserts / (Record no. 66424)

MARC details
000 -LEADER
fixed length control field 02920cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180602s2017 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.11.M.Sc.2017.Mo.P
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohamed Alaa Abdelfatah Hassan
245 10 - TITLE STATEMENT
Title Parametric study of double pipe heat exchangers with internal wavy tape inserts /
Statement of responsibility, etc. Mohamed Alaa Abdelfatah Hassan ; Supervised Essam E. Khalil Hassan Khalil , Gamal Abdelmoniem Elhariry , Taher Mohamed Aboudeif
246 15 - VARYING FORM OF TITLE
Title proper/short title دراسة بارامترية لأداء المبادلات الحرارية ذات الأنبوب المزدوج المزود بشرائح مموجة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mohamed Alaa Abdelfatah Hassan ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 75 P. :
Other physical details charts , facsimiles ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Mechanical Power Engineering
520 ## - SUMMARY, ETC.
Summary, etc. In the present study, Double pipe heat exchanger inserted with wavy tape turbulator is analysed numerically by solving the governing equations using ANSYS FLUENT 15.0 software. The thermal performance of the unit in the turbulent flow regime for Reynolds number range of 5000 {u2013} 25,000 is studied for different wavy tape geometries. Firstly, five different wavy tape angles of 45o, 60o, 90o, 120o and 150o are considered. Results showed that adding wavy tape increases the heat transfer rate up to 193% compared to plain tube coupled with a large value of the friction factor. It is seen that small wavy tape angles produce higher heat transfer enhancement and pressure drop. Also, wavy tape amplitude is investigated and the results showed that increasing wavy tape amplitude increases the heat transfer rate and also the pressure drop. Eventually, it is concluded that the ideal tape amplitude is about 54% of the pipe inner diameter. Finally, parametric model is developed in order to investigate the effect of the variation of different parameters on the performance of heat exchanging unit. Variations of inlet flow velocity of hot and cold streams are employed monitoring other performance parameters response. Results showed that variation of inlet velocity affects heat transfer rate and outlet temperatures of both streams. Also, effectiveness of heat exchanger is affected. Moreover, fouling of heat transfer surface is taken into consideration showing that fouling layer affects the response of performance parameters to velocity variations
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term CFD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Heat Transfer
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Thermal performance
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Essam E. Khalil Hassan Khalil ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Gamal Abdelmoniem Elhariry ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Taher Mohamed Aboudeif ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.11.M.Sc.2017.Mo.P 01010110075142000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.11.M.Sc.2017.Mo.P 01020110075142000 22.09.2023 CD - Rom 75142.CD