header

Accuracy of linear measurements of the planmeca promax 3D MID® cone beam computed tomography machine in different head orientations : (Record no. 67104)

MARC details
000 -LEADER
fixed length control field 03476cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032032.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180816s2017 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.05.M.Sc.2017.Na.A
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Nada Saeed Abdelhameed Mustafa
245 10 - TITLE STATEMENT
Title Accuracy of linear measurements of the planmeca promax 3D MID® cone beam computed tomography machine in different head orientations :
Remainder of title A diagnostic accuracy study /
Statement of responsibility, etc. Nada Saeed Abdelhameed Mustafa ; Supervised Sahar Hosny Eldessouky , Dina Mohamed Elbeshlawy
246 15 - VARYING FORM OF TITLE
Title proper/short title فى اوضاع مختلفه للرأس PlanmecaPromax 3D MID® دقة القياسات الخطيه للتصويرالمقطعي بالحاسوب مخروطي الشعاع لجهاز :
Remainder of title دراسة دقة تشخيصية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Nada Saeed Abdelhameed Mustafa ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 100 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral (Radiology and Diagnosis)
520 ## - SUMMARY, ETC.
Summary, etc. Nowadays, Cone beam computed tomography is widely used for both diagnosis and treatment planning in many dental fields providing precise three dimensional information about dental and maxillofacial structures with almost infinite number of image display options. Obtaining linear measurements is one of the very helpful facilities provided by all CBCT software and the dentists rely on such measurements for taking the right decision especially as regard implant placement, endodontic treatment as well as in cases requiring orthodontic intervention. The lack of accuracy of these linear measurements may lead to serious problems which might endanger the patient or adversely affect the treatment outcome. The patient{u2019}s head position during the CBCT scanning could deviate from the ideal one predetermined by each CBCT machine manufacturers. It is therefore important not only to assess the accuracy of linear measurements obtained from CBCT scans in standard scanning position, but also to examine the effect of improper head positioning on the accuracy of these measurements. Some controversies concerning the influence of changing the head positions on the accuracy of CBCT linear measurements were found on the previous studies. This study aimed to assess the accuracy of linear measurements of PlanmecaPromax 3D MID® CBCT machine in both standard and different head positions. Eleven dry human skulls were included in the study. Guttapercha markers were placed to define the distances to be measured in occluso-apical, bucco-lingual and mesio-distal dimensions. These 3 dimensions were measured in anterior, bilateral premolars and bilateral molars regions for each jaw and the skulls were imaged in standard and four different head positions (forward tilt, backward tilt, lateral tilt and rotation). Real measurements were taken using a digital caliper and CBCT measurements were performed by two radiologists separately
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term CBCT software
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Different head orientations
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Planmeca promax 3D MID®
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Dina Mohamed Elbeshlawy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Sahar Hosny Eldessouky ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.05.M.Sc.2017.Na.A 01010110075544000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.05.M.Sc.2017.Na.A 01020110075544000 22.09.2023 CD - Rom 75544.CD