Accuracy of linear measurements of the planmeca promax 3D MID® cone beam computed tomography machine in different head orientations : (Record no. 67104)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03476cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223032032.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 180816s2017 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.05.M.Sc.2017.Na.A |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Nada Saeed Abdelhameed Mustafa |
245 10 - TITLE STATEMENT | |
Title | Accuracy of linear measurements of the planmeca promax 3D MID® cone beam computed tomography machine in different head orientations : |
Remainder of title | A diagnostic accuracy study / |
Statement of responsibility, etc. | Nada Saeed Abdelhameed Mustafa ; Supervised Sahar Hosny Eldessouky , Dina Mohamed Elbeshlawy |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | فى اوضاع مختلفه للرأس PlanmecaPromax 3D MID® دقة القياسات الخطيه للتصويرالمقطعي بالحاسوب مخروطي الشعاع لجهاز : |
Remainder of title | دراسة دقة تشخيصية |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Nada Saeed Abdelhameed Mustafa , |
Date of publication, distribution, etc. | 2017 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 100 P. : |
Other physical details | charts , facsimiles ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral (Radiology and Diagnosis) |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Nowadays, Cone beam computed tomography is widely used for both diagnosis and treatment planning in many dental fields providing precise three dimensional information about dental and maxillofacial structures with almost infinite number of image display options. Obtaining linear measurements is one of the very helpful facilities provided by all CBCT software and the dentists rely on such measurements for taking the right decision especially as regard implant placement, endodontic treatment as well as in cases requiring orthodontic intervention. The lack of accuracy of these linear measurements may lead to serious problems which might endanger the patient or adversely affect the treatment outcome. The patient{u2019}s head position during the CBCT scanning could deviate from the ideal one predetermined by each CBCT machine manufacturers. It is therefore important not only to assess the accuracy of linear measurements obtained from CBCT scans in standard scanning position, but also to examine the effect of improper head positioning on the accuracy of these measurements. Some controversies concerning the influence of changing the head positions on the accuracy of CBCT linear measurements were found on the previous studies. This study aimed to assess the accuracy of linear measurements of PlanmecaPromax 3D MID® CBCT machine in both standard and different head positions. Eleven dry human skulls were included in the study. Guttapercha markers were placed to define the distances to be measured in occluso-apical, bucco-lingual and mesio-distal dimensions. These 3 dimensions were measured in anterior, bilateral premolars and bilateral molars regions for each jaw and the skulls were imaged in standard and four different head positions (forward tilt, backward tilt, lateral tilt and rotation). Real measurements were taken using a digital caliper and CBCT measurements were performed by two radiologists separately |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | CBCT software |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Different head orientations |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Planmeca promax 3D MID® |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Dina Mohamed Elbeshlawy , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Sahar Hosny Eldessouky , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Shimaa |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.05.M.Sc.2017.Na.A | 01010110075544000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.05.M.Sc.2017.Na.A | 01020110075544000 | 22.09.2023 | CD - Rom | 75544.CD |