header

Effect of using equator versus self-aligning attachment on quality of life and overdenture retention for patients restored by implant-retained mandibular overdentures : (Record no. 67129)

MARC details
000 -LEADER
fixed length control field 03245cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032033.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180825s2017 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.Ph.D.2017.Ah.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ahmad Zakaria Ali Aladl
245 10 - TITLE STATEMENT
Title Effect of using equator versus self-aligning attachment on quality of life and overdenture retention for patients restored by implant-retained mandibular overdentures :
Remainder of title Randomized clinical trial /
Statement of responsibility, etc. Ahmad Zakaria Ali Aladl ; Supervised Amal Fathy Kaddah , Ahmed Emad Fayyad
246 15 - VARYING FORM OF TITLE
Title proper/short title دراسة تأثير استخدام وصلات الإكويتور مقابل الوصلات ذاتية المحاذاه على درجه استبقاء الاطقم السفليه المثبته علي غرسات حامله مع فحص كفاءة الحياه لكل منهما :
Remainder of title دراسة سريرية عشوائية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ahmad Zakaria Ali Aladl ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 106 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontic
520 ## - SUMMARY, ETC.
Summary, etc. Two implant retained mandibular overdenture is a simple solution in rehabilitation of edentulous patients. Equator attachment offers a lower profile than the self-aligning attachment but there is no enough researches that compare between them. Aim: Clinically compare between both groups regarding oral health related quality of life and overdenture retention in edentulous patients restored with implant overdenture. Material and Methods: Complete denture fabricated, then two implants placed at the canine region. Equator attachments connected to group I and self-aligning attachments connected to each group II. The Arabic version of the oral health impact profile for the edentulous patients was used specifically to evaluate the impact of implant prosthesis on the patient's quality of life. Overdenture retention was measured according to the method reported by (Jose F. Mañes et al., 2011) using a spring scale to measure retention strength (in newton). Results: Regarding oral health related quality of life, there was statistically significant improvement from time of insertion to 3 months in both groups. There was no statistically significant difference between both groups at insertion time and after 3 months. Regarding overdenture retention, there was decrease of retention from time of insertion to 3 months follow-up periods with statistically significant difference in both groups of study. Equator group showed statistically significant more retention force compared to that of locator group at time of insertion, however, there was no statistically significant difference between two groups at 3 months follow-up period
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Equator attachment
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Quality of Life
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Self-Aligning attachment
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Emad Fayyad ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Amal Fathy Kaddah ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.Ph.D.2017.Ah.E 01010110075564000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.Ph.D.2017.Ah.E 01020110075564000 22.09.2023 CD - Rom 75564.CD