header

Influence of cleaning solution (Ivoclean) on the retention of saliva contaminated zirconia based copings using a novel bioactive cement (ceramir) : (Record no. 67288)

MARC details
000 -LEADER
fixed length control field 04063cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032038.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180903s2017 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.Ph.D.2017.Mo.I
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohamed Ashraf Hassan Mokhtar
245 10 - TITLE STATEMENT
Title Influence of cleaning solution (Ivoclean) on the retention of saliva contaminated zirconia based copings using a novel bioactive cement (ceramir) :
Remainder of title In-vitro study /
Statement of responsibility, etc. Mohamed Ashraf Hassan Mokhtar ; Supervised Eman Mohamed Anwar , Jylan Fouad Elguindy , Nadia Fahmy Zakaria
246 15 - VARYING FORM OF TITLE
Title proper/short title تأثر محلول التنظيف (ايفوكلين) علي استبقاء الاغطية المصنعة من الزيركونيا الملوثة باللعاب باستخدام اسمنت مستحدث حيوي نشط سيرامير :
Remainder of title دراسة في المختبر
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mohamed Ashraf Hassan Mokhtar ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 99 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. The present study investigated the effect of Ivoclean cleaning paste on the pull out test of saliva contaminated zirconia copings cemented with a bioactive cement Ceramir A total of 36 multi-rooted caries free human maxillary molar teeth were collected. All teeth was positioned perpendicular to the base of a stainless steel cylinder using a custom device and embedded in the cylinder with epoxy resin In order to standardize the preparation of all samples, teeth were machined milled using a multi-function milling machine to achieve a standardized crown preparation of 20 degree total convergence angle and 1 mm circumferential finish line. Each abutment was scanned and the copings were designed using interactive CAD software. An occlusal extension with an occlusal hole was added to the coping design to facilitate the coping removal during the test. Zirconia copings received airborne particles abrasion with 50 æm alumina-oxide (Al2O3 ) particles. Samples were then divide in to 3 groups: Group (I) (n=12): Zirconia Copings cemented with ceramir cement without saliva contamination (control). Group (II) (n=12): Saliva contaminated zirconia copings cemented with Ceramir cement Group (III) (n=12): Application of cleansing paste (Ivoclean) in saliva contaminated zirconia copings cleaned with cleansing paste and cemented with Ceramir cement The tooth surface was cleaned using air-water spray then was gently dried with compressed air. While the zirconia copings in groups 2 and 3 were immersed in saliva for 1m followed by cleaning with air-water spray for 15 sec. and dried with compressed air for another 15 sec. followed by the application of Ivoclean cleaning paste in group 3 zirconia coping samples. A cementation device with 5kg load was used with all zirconia based coping to standardize load application during the cementation procedure. Testing the samples All samples were then subjected to thermocycling 5000 cycle, then the cemented specimens were mounted in a jig attached to a universal testing machine to measure the retentive pull out tensile load of the material. A tensile mode of force was applied via materials testing machine at a crosshead speed of 1 mm/min up to pull out the coping until cement failure. The maximum pull out load was recorded automatically in Newton via the computer software connected to the testing machine. Mode of failure was examined using photos with macrolense digital camera and scanning electron microscope
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Ceramir
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Ivoclean
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Zirconia based
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Eman Mohamed Anwar ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Jylan Fouad Elguindy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Nadia Fahmy Zakaria ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.Ph.D.2017.Mo.I 01010110075663000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.Ph.D.2017.Mo.I 01020110075663000 22.09.2023 CD - Rom 75663.CD