Assessment of the radiation dose in a medical linear accelerator using a simulation model and experimental verification / (Record no. 67439)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02007cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223032043.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 180912s2017 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.12.20.M.Sc.2017.Ah.A |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Ahmed Medhat Fahmy Moustafa |
245 10 - TITLE STATEMENT | |
Title | Assessment of the radiation dose in a medical linear accelerator using a simulation model and experimental verification / |
Statement of responsibility, etc. | Ahmed Medhat Fahmy Moustafa ; Supervised Hassan Fathy Ibrahim , Ehab Marouf Attalla |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | تقييم الجرعة الاشعاعية في الدعجل الخطي الطبي باستخدام نموذج للمحاكاة والتأكد التجريبي |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Ahmed Medhat Fahmy Moustafa , |
Date of publication, distribution, etc. | 2017 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 178 P. : |
Other physical details | charts , facsimiles ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Science - Department of Physics |
520 ## - SUMMARY, ETC. | |
Summary, etc. | This research aims to investigate the use of the Monte Carlo (MC) simulations (Geant4/GATE) to estimate the radiation doses for different field sizes at the isocenter from a medical linac. A water phantom is irradiated by using a 6 MV photon beam delivered by Siemens ONCOR linac. The percent depth doses and dose profiles at different depths are measured using two types of ionization chamber, then compared with the MC calculated data. The comparisons show satisfactory agreement with gamma index passing rates from 63.15% to 98.87%, therefore, MC simulations can be considered adequate for the assessment of the radiation doses from any medical linac |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Ionization chamber |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Medical linac |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Water phantom |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Ehab Marouf Attalla , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Hassan Fathy Ibrahim , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Shimaa |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.12.20.M.Sc.2017.Ah.A | 01010110075748000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.12.20.M.Sc.2017.Ah.A | 01020110075748000 | 22.09.2023 | CD - Rom | 75748.CD |