header

Optimal design and analysisof anti-resonance C-type passive filters / (Record no. 67693)

MARC details
000 -LEADER
fixed length control field 01807cam a2200301 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180927s2018 ua do f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.07.M.Sc.2018.Ah.O
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ahmed Lamloom Abdelwahab Mayhoob
245 10 - TITLE STATEMENT
Title Optimal design and analysisof anti-resonance C-type passive filters /
Statement of responsibility, etc. Ahmed Lamloom Abdelwahab Mayhoob ; Supervised Ahmed Mohamed Ibrahim
246 15 - VARYING FORM OF TITLE
Title proper/short title التصميم الأمثل و التحليل للمرشحات غير الفعالة المخمدة للرنين من النوع سى
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ahmed Lamloom Abdelwahab Mayhoob ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 64 P. :
Other physical details charts , photographs ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Electrical Power and Machines
520 ## - SUMMARY, ETC.
Summary, etc. Power system harmonics can be found in all commercial and industrial facilities. No doubt those non-linear loads are the main source of harmonic distortion in power systems. This is why electrical distribution systems are, nowadays, highly polluted with harmonics. Poor power factor, reduced network efficiency, and increased power losses are some consequences of harmonic distortion. One of the most adverse effects of harmonic distortion is harmonic resonance, which may significantly amplify harmonic voltages and currents. Thus, nowadays, the filters design trend is to design new resonance-free schemes that can damp resonance and mitigate harmonics
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Harmonics
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Power factor
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Resonance
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Mohamed Ibrahim ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.07.M.Sc.2018.Ah.O 01010110076035000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.07.M.Sc.2018.Ah.O 01020110076035000 22.09.2023 CD - Rom 76035.CD