header

Validity and reliability of laser goniometer in measuring range of motion in healthy subjects / (Record no. 67854)

MARC details
000 -LEADER
fixed length control field 03429cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032056.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 181008s2018 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.21.09.Ph.D.2018.Wa.V
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Wael Osama Aly Abdelkhalek
245 10 - TITLE STATEMENT
Title Validity and reliability of laser goniometer in measuring range of motion in healthy subjects /
Statement of responsibility, etc. Wael Osama Aly Abdelkhalek ; Supervised Mohamed Hussein Elgendy
246 15 - VARYING FORM OF TITLE
Title proper/short title صحة و دقة الليزر جونيومتر في قياس المدي الحركي في الأشخاص الأصحاء
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Wael Osama Aly Abdelkhalek ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 86 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Physical Therapy - Department of Basic Science
520 ## - SUMMARY, ETC.
Summary, etc. Background:Methods of objective assessment of range of motion are limited, one of the best but expensive standardized methods is the electro-goniometer, and one of the new methods that arises recently is the laser goniometer.Purpose:The purpose of this study was:1) to investigate the concurrent validity of the laser goniometer via correlating and comparing its repeated measures with those of electro-goniometer considering the electro-goniometer as the reference standard. 2) to investigate theintra-rater reliability of the laser goniometer through measuring the degree of consistencyof its readingsonrepeated measures.Subjects:participants in this study wereone hundred healthy male students and colleagues at MisrUniversity for Science and Technology. Their ages ranged between 20-30 years.Methods:Average ofthree consecutive measures was taken by the same examiner forthe active range of motion of cervical, shoulder and knee bilaterallyfor each subject by each of the laser and electro-goniometers, keeping the standardization of measurement procedures,subjects{u2019} positions and stabilizationsconstant all over the measurement period.Research design:A one group within-subject test research design was used in this study. Results:1)Pearson correlation coefficient (r) and paired T-testhad been used to investigate the concurrent validity of the laser goniometer.The results of correlation coefficient values showed moderate relation for cervical flexion and strong relation for all other cervical motions,and very strong relation for bilateral shoulder flexion, external and internal rotation and right knee flexion motions, and excellent relation for bilateral shoulder abduction and left knee flexion movements.Also there was no significant difference between measures obtained by both devices for all movements except for cervical flexion which showed that the laser goniometer provided significantly higher readings than those of the electro-goniometer.2) Intra-class Correlation Coefficient (ICC)had been used to investigate the intra-rater reliability of the laser goniometer and the results revealed thatthe laser goniometer has provedvery high reliability values
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Electro-Goniometer
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Laser Goniometer
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Range of Motion Assessment
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Hussein Elgendy ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.21.09.Ph.D.2018.Wa.V 01010110076068000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.21.09.Ph.D.2018.Wa.V 01020110076068000 22.09.2023 CD - Rom 76068.CD