header

A simulation study of n-butane absorption refrigeration system using commercial hydrocarbons as absorbents / (Record no. 67917)

MARC details
000 -LEADER
fixed length control field 02535cam a2200313 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 181013s2018 ua d f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.04.M.Sc.2018.Mu.S
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Muhammad Mustafa Muhammad Ahmad Arafia
245 12 - TITLE STATEMENT
Title A simulation study of n-butane absorption refrigeration system using commercial hydrocarbons as absorbents /
Statement of responsibility, etc. Muhammad Mustafa Muhammad Ahmad Arafia ; Supervised Ahmed Soliman Mohamed Fawzy , Ayat Ossama Ghallab
246 15 - VARYING FORM OF TITLE
Title proper/short title دراسة محاكاة نظام التثليج الإمتصاصي بالبيوتان بإستخدام المذيبات الهيدروكربونية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Muhammad Mustafa Muhammad Ahmad Arafia ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 138 P. :
Other physical details charts ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Chemical Engineering
520 ## - SUMMARY, ETC.
Summary, etc. The performance of a single-effect absorption chiller operating with commercial butane as a refrigerant and six commercial hydrocarbons as absorbents was studied. The main parameters for an absorption refrigeration system, using the proposed working fluids, were compared at different operating conditions to select the optimal working fluids. Moreover, a special focus was given to the effect of operating conditions and butane recovery on the performance of the optimal systems. Finally, the performance of the optimal systems was examined in contrast to that of the commercial absorption chillers and to that of the traditional vapor-compression chiller. Results revealed that the best performance was achieved by butane/heavy naphtha and by butane/light reformate. The COP passed through a different maximum value at certain recovery at different operating conditions. Low reboiler temperatures were feasible at low butane recoveries with almost the same COP. Butane/heavy naphtha could compete effectively with the commercial absorption chillers, whereas butane/light reformate showed lower COP values but had lower reboiler temperatures. Compared to vapor-compression chiller, the proposed systems saved a significant amount electric power
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Absorption
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Chiller
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Refrigeration
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Soliman Mohamed Fawzy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ayat Ossama Ghallab ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.04.M.Sc.2018.Mu.S 01010110076118000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.04.M.Sc.2018.Mu.S 01020110076118000 22.09.2023 CD - Rom 76118.CD