header

A comparative study for a new technique of endotracheal intubation using medan video assisted laryngoscope on a standardized manikin with a normal airway / (Record no. 68179)

MARC details
000 -LEADER
fixed length control field 03171cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 181027s2018 ua h f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.01.M.Sc.2018.Ma.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mahmoud Mohamed Adly Ibrahim
245 12 - TITLE STATEMENT
Title A comparative study for a new technique of endotracheal intubation using medan video assisted laryngoscope on a standardized manikin with a normal airway /
Statement of responsibility, etc. Mahmoud Mohamed Adly Ibrahim ; Supervised Nadia Youssef Hamed Helmy , Maha Mohammed Ismail Youssef , Ghada AboBakr Mohamed Elsherif
246 15 - VARYING FORM OF TITLE
Title proper/short title دراسه مقارنه لتقنية جديدة لوضع الانبوبة الحنجرية بواسطة منظار حنجرى يستعمل خاصية الصورة على دمية مماثلة للطبيعة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mahmoud Mohamed Adly Ibrahim ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 74 P. :
Other physical details facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Anaesthesia
520 ## - SUMMARY, ETC.
Summary, etc. Background: This study compared between the conventional technique of endotracheal intubation using medan video assisted laryngoscope using a stylet as recommended by the manufactures for high curved blade video laryngoscopes versus a new technique not using a stylet concerning intubation time and the success rate. Methods and material: 25 residents in the final year of residency were included in this study, every resident was allowed to have 2 trials of intubation using medan video assisted laryngoscope on a manikin with a standardized airway, the first trial was with the standard conventional technique and the second with the new technique, Every resident was informed about the new video assisted laryngoscope to get familiar with and the standard method of intubation recommended by the manufactures then the resident was allowed to have the 2 trials, the first trial was to intubate the same manikin with normal airway that was used for all residents with the standard conventional method .The resident would then had to remove the laryngoscope and the tube from the manikin and the 2nd trial was allowed by the same resident after instructing him to reach the base of the epiglottis then withdraw the laryngoscope backward until the tip of the epiglottis is seen as a rim crescent in the upper part of the screen and then to elevate it up and laterally to open the view and try to intubate. The 2 trails of every resident in the study were classified into 2 groups according to the technique used during the trial of intubation i.e first trial for intubation by conventional technique (group 1) versus second trial for intubation by the same resident by new technique group 2
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Medan video laryngoscope
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Stylet
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Time of intubation
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ghada AboBakr Mohamed Elsherif ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Maha Mohammed Ismail Youssef ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Nadia Youssef Hamed Helmy ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.01.M.Sc.2018.Ma.C 01010110076257000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.01.M.Sc.2018.Ma.C 01020110076257000 22.09.2023 CD - Rom 76257.CD