header

Knee derangement : (Record no. 68180)

MARC details
000 -LEADER
fixed length control field 02001cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032106.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 181027s2018 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.31.M.Sc.2018.Sh.K
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Sherihan Salah Kamal Mohamed Elseufi
245 10 - TITLE STATEMENT
Title Knee derangement :
Remainder of title Can a single isotropic 3D fast spin echo sequence replace three-plane standard 2d fast spin echo sequences? /
Statement of responsibility, etc. Sherihan Salah Kamal Mohamed Elseufi ; Supervised Heba Ahmed Kamal , Amr Samir Rashwan , Maged Abdelrahman Hawana
246 15 - VARYING FORM OF TITLE
Title proper/short title دور التصوير بالرنين المغناطيسي بطريقة الدوران الجزيئي السريع - ثلاثي الأبعاد في تشخيص اعتلال الركبة مقارنة بطريقة الدوران الجزيئي السريع - ثنائي الأبعاد
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Sherihan Salah Kamal Mohamed Elseufi ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 81 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Radio-diagnosis
520 ## - SUMMARY, ETC.
Summary, etc. The diagnostic performance of the 3D Spin Echo (FSE) Sequence has been shown to be similar to that of the standard 2D sequences in the assessment of internal structures of the knee, such as ligaments and menisci ,this capability makes this sequence an attractive option for use in clinical practice. This 3D imaging sequence seems to provide a multiplanar reformation (MPR).The imaging time using 3D MRI is shorter than 2D MRI
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Knee derangment
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term MRI 2D
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term MRI 3D
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Amr Samir Rashwan ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Heba Ahmed Kamal ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Maged Abdelrahman Hawana ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.31.M.Sc.2018.Sh.K 01010110076284000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.31.M.Sc.2018.Sh.K 01020110076284000 22.09.2023 CD - Rom 76284.CD