header

Effect of stadium geometry on spectators area flow pattern / (Record no. 68773)

MARC details
000 -LEADER
fixed length control field 01860cam a2200313 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 181127s2018 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.11.M.Sc.2018.Ac.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Acer Mohy Eldeen Hassan Ahmed Ali
245 10 - TITLE STATEMENT
Title Effect of stadium geometry on spectators area flow pattern /
Statement of responsibility, etc. Acer Mohy Eldeen Hassan Ahmed Ali ; Supervised Mahmoud Ahmed Fouad , Kareem Awny
246 15 - VARYING FORM OF TITLE
Title proper/short title تأثيرشكل الاستاد على نمط الهواء في منطقة المشجعين
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Acer Mohy Eldeen Hassan Ahmed Ali ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 115 P. :
Other physical details charts , facsimiles ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Mechanical Power Engineering
520 ## - SUMMARY, ETC.
Summary, etc. The current research spots the light on the main parameter that affects the air flow pattern inside the stadium, where the analysis proved the importance of the attachment of the free shear layer on the stadium's roof where it is the major parameter that affects the whole air flow inside the stadium. Furthermore, the research provide many tools to control the free shear layer to achieve the required air velocities regarding to the stadium ventilation whether it exists in regions with warm or hot climates or in regions with cold climates. Eventually the current research initiated a new perspective for the semi-open stadium design that starts many further research in this field
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Free shear layer
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Roof effect
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Stadium Ventilation
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Kareem Awny ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mahmoud Ahmed Fouad ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.11.M.Sc.2018.Ac.E 01010110076451000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.11.M.Sc.2018.Ac.E 01020110076451000 22.09.2023 CD - Rom 76451.CD