header

Validity of clinical assessment measures of static foot posture in children / (Record no. 68924)

MARC details
000 -LEADER
fixed length control field 02890cam a2200313 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 181204s2018 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.21.06.Ph.D.2018.Em.V
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Emad Abdelmaboud Mahmoud Elsayed Aboelnasr
245 10 - TITLE STATEMENT
Title Validity of clinical assessment measures of static foot posture in children /
Statement of responsibility, etc. Emad Abdelmaboud Mahmoud Elsayed Aboelnasr ; Supervised Hoda Abdelazim Eltalawy , Faten Hassan Abdelazim
246 15 - VARYING FORM OF TITLE
Title proper/short title مصداقية التقيم الاكلينيكي لقوام القدم الساكن عند الاطفال
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Emad Abdelmaboud Mahmoud Elsayed Aboelnasr ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 123 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Physical Therapy - Department of Growth and Development Disorders in Pediatrics
520 ## - SUMMARY, ETC.
Summary, etc. Background : Although reliability of clinical measures of static foot posture has been widely debated, validity of these measures has not been fully established especially in paediatric population. Clinicians are in need for a valid, accurate, easily used, noninvasive, safe and cost effective measure to evaluate static foot posture clinically. Objectives: To investigate validity and diagnostic accuracy of three clinical measures of static foot posture (foot posture index-6, Clarke{u2019}s angle, Normalized truncated navicular height) in children and adolescents using radiographic measures as the gold standard measure. Methods: A cross-sectional descriptive study had been conducted on a sample of 612 participants aged 6-18 years (12.36 ±3.39). Clinical assessment of static foot posture using Clarke{u2019}s angle, foot posture index-6 and normalized truncated navicular height was compared to the gold standard radiographic measures and displayed on the receiver operating characteristics curve. Intra-rater reliability was investigated using intraclass correlation coefficient. Sensitivity, specificity, predictive values, likelihood ratios were calculated for the studied clinical measures. Results: Clarke{u2019}s angle demonstrated the highest intra-rater reliability (ICC=0.99), followed by NTNH (ICC= 0.97) and FPI-6(ICC=0.96). CA was the most sensitive (98.4%) and specific (98.8%) measure and demonstrated the highest positive predictive value (97.3), negative predictive value (99.3), positive likelihood ratio (84) and the lowest negative likelihood ration (0.02) among the studied clinical measures
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Children
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Static foot posture
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Validity
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Faten Hassan Abdelazim ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hoda Abdelazim Eltalawy ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Enas
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.21.06.Ph.D.2018.Em.V 01010110076455000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.21.06.Ph.D.2018.Em.V 01020110076455000 22.09.2023 CD - Rom 76455.CD