header

Rejected heart beat effect in cardiac gated spect on imaging quality and ejection fraction accuracy / (Record no. 69459)

MARC details
000 -LEADER
fixed length control field 02769cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032145.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190109s2017 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.12.04.M.Sc.2017.Mo.R
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohamad Abdullah Abdelhady Abdelaziz
245 10 - TITLE STATEMENT
Title Rejected heart beat effect in cardiac gated spect on imaging quality and ejection fraction accuracy /
Statement of responsibility, etc. Mohamad Abdullah Abdelhady Abdelazizm; Supervised Ahmed Soltan Abdelmonem , Mahmoud Hany Khedr
246 15 - VARYING FORM OF TITLE
Title proper/short title دراسه تأثير نبضات القلب الغير منتظمه علي جوده صور و دقه حسابات كفائه عضله القلب في فحص المسح الذري علي عضله القلب
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mohamad Abdullah Abdelhady Abdelaziz ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 95 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Science - Department of Biophysics
520 ## - SUMMARY, ETC.
Summary, etc. Background{u02D0} gated myocardial perfusion spect (g-spect) is considered as one of the best techniques for the combined evaluation of the myocardial perfusion and the left ventricular ejection fraction (lvef) within a single study. sufficient count density in the cine frames is a necessary for best myocardial perfusion images quality while g- spect synchronized with the subject{u2019}s electro cardio gram (ecg) is also necessary to identify the temporal phases of the cardiac cycle. the variation in the cardiac cycle duration may cause fluctuation of the adjacent frames count which compromises the quality of perfusion image and decrease ef accuracy. this study investigates the factors (arrhythmia and gating errors) that affecting the perfusion images quality and decrease the ejection fraction (ef) accuracy. Methods{u02D0} this study were performed on fifty-two patients classified into two groups 35 nonarrhythmic patients (group 1) and 17 arrhythmic patients (group 2). each patient will have two consequent stress g-spect acquisitions one of them will be taken with time dependant projections (tdp sec), and the other with accepted beats projections (abp). then we calculate lvef for both acquisitions and compare them with echocardiogram ef. then we compare the g-spect perfusion images with the non- gated spect perfusion images
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Accepted heart beats
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Arrhythmia effect
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Rejected heart beats
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Soltan Abdelmonem ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mahmoud Hany Khedr ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.12.04.M.Sc.2017.Mo.R 01010110076733000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.12.04.M.Sc.2017.Mo.R 01020110076733000 22.09.2023 CD - Rom 76733.CD