header

Effect of two different stud attachments on the retention and stresses induced around implants retaining unilateral total maxillectomy obturator : (Record no. 69696)

MARC details
000 -LEADER
fixed length control field 02803cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032152.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190122s2018 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2018.Ar.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Arwa Sedky Abdellateef Mawas
245 10 - TITLE STATEMENT
Title Effect of two different stud attachments on the retention and stresses induced around implants retaining unilateral total maxillectomy obturator :
Remainder of title Invitro study /
Statement of responsibility, etc. Arwa Sedky Abdellateef Mawas ; Supervised Maha Wagdy Elkerdawy , Khaled Aziz Mohamed Abdelwahab
246 15 - VARYING FORM OF TITLE
Title proper/short title تأثير نوعين من الوصلات التعشيقيه علي الاستبقاء والضغوط المتولده حول الغرسات الداعمه للسده المستخدمه بعد الاستئصال الكلي لنصف الفك العلوي
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Arwa Sedky Abdellateef Mawas ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 101 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. In this invitro study, the effect of two different stud attachments (ball & locator) on the retention and stresses induced around implants retaining unilateral total maxillectomy obturator was studied. This study was carried out on an acrylic resin model constructed from duplication of a study model of unilateral total maxillectomy. Three dummy implants 3.7 in diameter and 11 mm in length were installed at the sites of first central incisor, first premolar and second molar of the non-defect side. The test obturator was processed. Six strain gauges were attached to the buccal and mesial surfaces of the prepared model around each implant. The experiment was divided into 2 phases: first with ball and socket attachment followed by locator attachment.Once retention and stress analysis studies were completed for the ball attachments, they were replaced by locator attachment. Universal testing machine was used to measure the retentive forces of the studied attachments. At the same time, strain-meter was used to record the microstrains transmitted to each strain gauge while the machine was adjusted to move in tensile mode. The collected data were tabulated and statistically analyzed
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Retention and stresses induced around implants
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Two different stud attachments
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Unilateral total maxillectomy obturator
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Khaled Aziz Mohamed Abdelwahab ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Maha Wagdy Elkerdawy ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2018.Ar.E 01010110076885000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2018.Ar.E 01020110076885000 22.09.2023 CD - Rom 76885.CD