header

Optimization of the performance of grid-connected wind{u2013}driven double-fed induction generator / (Record no. 69774)

MARC details
000 -LEADER
fixed length control field 01863cam a2200313 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190127s2018 ua do f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.07.M.Sc.2018.Ay.O
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ayman Mohamed Abdalsamie Abdalhaliem
245 10 - TITLE STATEMENT
Title Optimization of the performance of grid-connected wind{u2013}driven double-fed induction generator /
Statement of responsibility, etc. Ayman Mohamed Abdalsamie Abdalhaliem ; Supervised Adel Shaltout , Hussein Abdelkhalek Attia
246 15 - VARYING FORM OF TITLE
Title proper/short title التشغيل الامثل لمولدات الحث ذات التغذية المزدوجة المدارة بطاقة الرياح والمتصلة بالشبكة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ayman Mohamed Abdalsamie Abdalhaliem ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 88 P. :
Other physical details charts , photographs ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Electrical Power and Machines
520 ## - SUMMARY, ETC.
Summary, etc. A complete study of the effect of injecting the rotor of the double fed induction generator with a voltage that is variable in both magnitude and phase angle which resulted in optimization of the performance of the double fed induction generator to achieve the point of maximum power extracted from wind and one of two options, either obtaining minimum losses or operating at a preset power factor value. A comparison has been conducted between the double fed induction generator performance using the employed control strategies and the single fed induction generator
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Induction generator
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Turbine
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Wind
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Adel Shaltout ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hussein Abdelkhalek Attia ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Asmaa
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.07.M.Sc.2018.Ay.O 01010110076970000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.07.M.Sc.2018.Ay.O 01020110076970000 22.09.2023 CD - Rom 76970.CD