MARC details
000 -LEADER |
fixed length control field |
02373cam a2200325 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
190216s2018 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.11.24.M.Sc.2018.Ze.E |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Zeina Mohsen Naguib Emadeldin Salem |
245 14 - TITLE STATEMENT |
Title |
The effect of corneal collagen crosslinking on intraocular pressure readings / |
Statement of responsibility, etc. |
Zeina Mohsen Naguib Emadeldin Salem ; Supervised Karim Adly Raafat , Sherif Ali Gamal Eldin , Ahmed Mohamed Ali Sherif |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
تأثير تشبيك روابط كولاجين القرنية على قراءات ضغط العين |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Zeina Mohsen Naguib Emadeldin Salem , |
Date of publication, distribution, etc. |
2018 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
74 P. : |
Other physical details |
charts , facsimiles ; |
Dimensions |
25cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Ophthalmology |
520 ## - SUMMARY, ETC. |
Summary, etc. |
Purpose To evaluate the Goldmannapplanation tonometer (GAT) and the ocular response analyzer (ORA) tonometer in measuring intraocular pressure (IOP) in keratoconic eyes and eyes with post lasikectasia before and after riboflavin/ultraviolet A corneal collagen crosslinking (CXL), to assess agreement among devices and to analyze the impact of some ocular parameters on their measurements. Patients and Methods This prospective non comparative study included thirty eyes of 17 patients who had undergone corneal collagen crosslinking (CXL) to arrest progression of keratoconus or post LASIK ectasia. Intraocular pressure readings were taken by Goldmannapplanation tonometer and Ocular ResponseAnalyzer. The IOP was measured by the two techniques before the procedure of CXL and again 1 week, 1 month and 3 months after the procedure.Three reliable measurements were obtained from each eye and the mean was taken each time. Other changes were also analyzed before and after the CXL; such as central corneal thickness, corneal resistance factor and cornealhysteresis |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Goldmannapplanation tonometer |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Intraocular pressure |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Keratoconus |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Ahmed Mohamed Ali Sherif , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Karim Adly Raafat , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Sherif Ali Gamal Eldin , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Shimaa |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |