header

Clinical and radiographic evaluation of dimensional changes of immediate peri-implant gaps in the upper premolar area with and without placement of xenograft bone substitute : (Record no. 70637)

MARC details
000 -LEADER
fixed length control field 03063cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032220.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190304s2018 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.08.M.Sc.2018.Ma.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mahmoud Medhat Mahmoud
245 10 - TITLE STATEMENT
Title Clinical and radiographic evaluation of dimensional changes of immediate peri-implant gaps in the upper premolar area with and without placement of xenograft bone substitute :
Remainder of title A randomized controlled clinical trial /
Statement of responsibility, etc. Mahmoud Medhat Mahmoud ; Supervised Mona Darhous , Amr Zahran , Amira Maged
246 15 - VARYING FORM OF TITLE
Title proper/short title التقييم السريرى و الأشعاعي للتغيير في أبعاد الفجوات العظمية حول الزرعات الفورية في منطقة مفترق الجذور في الضواحك العلوية مع و بدون استخدام البدائل العظمية المستمدة من الأبقار :
Remainder of title تجربه إكلينيكية عشوائية محكمة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mahmoud Medhat Mahmoud ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 139 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Periodontology
520 ## - SUMMARY, ETC.
Summary, etc. This study was performed to investigate tissue alteration following immediate implant placement, 16 Maxi-Z two piece implants were placed in 16 patients with teeth indicated for extraction in the area of maxillary premolar teeth. All the patients were free from systemic diseases and non-smokers Each patient received proper oral hygiene instructions and a full mouth scaling and root planning.Cone Beam Computed Tomography (CBCT) was taken to evaluate the area of extraction. The preoperative radiographs were used to confirm the diagnosis and estimate the implant length. All Patients were thoroughly informed of the immediate placement protocol and all the risks associated with this procedure and signed up the consent form.The procedures started by the administration of a local anesthetic, followed by careful atraumatic tooth extraction using elevator and the forceps to deliver the tooth out. After extraction, the integrity of the buccal plate of bone checked using an osteotomy probe through the fresh extraction socket as intact buccal plate of bone was considered crucial.The extracted roots measured in buccolingual and mesiodistal dimension at the middle third using a periodontal probe and the readings were averaged, this helped to choose the correct implant diameter.The length of the implant obtained from the cone beam computed tomography
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Peri-implant
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Radiographic evaluation
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Xenograft bone
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Amira Maged ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Amr Zahran ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mona Darhous ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.08.M.Sc.2018.Ma.C 01010110077298000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.08.M.Sc.2018.Ma.C 01020110077298000 22.09.2023 CD - Rom 77298.CD