Predictive value of ultrasound in detection of complications after one hour of renal biopsy / (Record no. 71388)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02859cam a2200349 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223032243.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 190411s2018 ua h f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.11.28.M.Sc.2018.Am.P |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Amina Mohamed Abdelfatah Kholeif |
245 10 - TITLE STATEMENT | |
Title | Predictive value of ultrasound in detection of complications after one hour of renal biopsy / |
Statement of responsibility, etc. | Amina Mohamed Abdelfatah Kholeif ; Supervised Mervat Ahmed Haroun , Amr Mohamed Salem , Rasha Helmy Mohamed |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | دور الموجات الصوتية بعد ساعة من أخذ عينة من الكلي في اظهار المضاعفات |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Amina Mohamed Abdelfatah Kholeif , |
Date of publication, distribution, etc. | 2018 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 92 P. : |
Other physical details | facsimiles ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Pediatrics |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Renal biopsy became a standard technique in diagnosing renal diseases. It held many complications in the past being performed blindly. But since the introduction of ultrasound guided renal biopsy in the field, the procedure became much safer with less complication rate and better yield. Objectives: In this study we aim to evaluate the capability of ultrasound examination after one hour to detect early complication and predict the course of cases. Patients and methods: This was a prospective study conducted during the period from October 2017 to the end of March 2018, and included patients undergoing Percutaneous Renal Biopsy in the Pediatric Nephrology Unit in Cairo University Pediatric Hospitals. Results: The present study was conducted on 60 patients; 29 were males (48.3%) and 31 were females (51.7%); their mean weight was 24.2 kg, with mean age 89.3 months. Out of 60 patients who performed the biopsy, only 21.6% had complications. We detected two subcapsular hematomas (3.3%), another 2 cases with bladder hematoma (3.3%), 9 cases with back pain (15%) and hematuria (as a complication, not related to original disease) occurred in 6 cases (10%). We found that sensitivity of ultrasound is 66.6% in the first hour after renal biopsy with 98.3 % specificity to possible bleeding complications with 66.6% positive predictive value and 98.2% negative predictive value. However clinical presentation was the only predictor in one case for complication which was detected late by ultrasound |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Complications |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Renal biopsy |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Ultrasound |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Amr Mohamed Salem , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Mervat Ahmed Haroun , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Rasha Helmy Mohamed , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Asmaa |
Reviser | Cataloger |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.11.28.M.Sc.2018.Am.P | 01010110077618000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.11.28.M.Sc.2018.Am.P | 01020110077618000 | 22.09.2023 | CD - Rom | 77618.CD |