header

Clinical evaluation of the fracture resistance for E-max CAD and Vita Suprinity laminate veneers / (Record no. 71839)

MARC details
000 -LEADER
fixed length control field 02172cam a2200313 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190506s2018 ua h f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2018.Ah.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ahmed Mohamed Osman
245 10 - TITLE STATEMENT
Title Clinical evaluation of the fracture resistance for E-max CAD and Vita Suprinity laminate veneers /
Statement of responsibility, etc. Ahmed Mohamed Osman ; Supervised Jylan Fouad Elguindy , Karim Aboubakr Mohamed
246 15 - VARYING FORM OF TITLE
Title proper/short title (التقويم الاكلينيكي لمقاومة كسر الوجوة التجميلية المصنعة من(ايماكس كاد) و المصنعة من( سبرنتي
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ahmed Mohamed Osman ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 86 P. :
Other physical details facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. Ceramic laminate veneers show a successful esthetic and functional long-term service for their perfect color match, marginal integrity and mechanical properties. The minimum-thickness, ceramic laminate veneers are a conservative and esthetic alternative to reestablish the form, shape and color of anterior teeth. Mechanical behavior and marginal integrity are the major factors that affect the long-term prognosis of any restorations. This clinical study was done to evaluate the clinical performance(in terms of fracture resistance, marginal adaptation, retention, and sensitivity) for two different materials VITA SUPRINITY and e.max CAD used for the fabrication anterior ceramic laminate veneers. Twenty four ceramic laminate veneers were fabricated for maxillary anterior teeth. The patients were divided into two groups according to the material Group 1(control group) fabricated from e.max CAD laminate
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term E-max CAD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Fracture resistance
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Vita Suprinity
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Jylan Fouad Elguindy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Karim Aboubakr Mohamed ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Asmaa
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2018.Ah.C 01010110078040000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2018.Ah.C 01020110078040000 22.09.2023 CD - Rom 78040.CD