header

Dimensional accuracy of maxillary complete denture base fabricated by rapid prototyping method compared with the conventional method : (Record no. 71840)

MARC details
000 -LEADER
fixed length control field 02606cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032256.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190506s2018 ua do f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2018.Ta.D
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Tarek Salah Hashim Ali
245 10 - TITLE STATEMENT
Title Dimensional accuracy of maxillary complete denture base fabricated by rapid prototyping method compared with the conventional method :
Remainder of title A randomized controlled trial /
Statement of responsibility, etc. Tarek Salah Hashim Ali ; Supervised Mahmoud Elfar , Nora Cheta
246 15 - VARYING FORM OF TITLE
Title proper/short title مقارنة بين قاعدة طقم الأسنان العلوي المصنع بأستخدام تقنية التصنيع السريع والمصنع بأستخدام التقنية التقليدية من حيث دقة الأبعاد :
Remainder of title دراسه عشوائيه خاضعه للتحكم
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Tarek Salah Hashim Ali ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 70 P. :
Other physical details charts , photographs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. In-vivo study was carried out to evaluate the amount of the linear dimensional changes of maxillary complete denture fabricated by using Digital Light Projection (DLP) 3D printing method and conventional compression flask method. Eighteen completely edentulous patients were included in the study. For each patient, the maxillary master cast was used to fabricate duplicate. The obtained duplicates were used to fix three cover screws at the following positions; A: the incisive papilla, B: the right second molar area, C: the left second molar. Patients were divided into two equal groups of nine participants, Group (1) the conventionally processed complete denture and Group (2) the Digital Light Projection (DLP) 3D printed complete denture. The dimensional changes were measured using Digital caliper with accuracy of 0.02mm. Dimensional changes occurred in both types of complete dentures bases. Digital Light Projection (DLP) 3D printed complete dentures showed more dimensional stability than the Conventional Compression flask complete dentures with no statistical significance
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term 3D printing
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Complete denture
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Conventional compression flask
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mahmoud Elfar ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Nora Cheta ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Asmaa
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2018.Ta.D 01010110078041000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2018.Ta.D 01020110078041000 22.09.2023 CD - Rom 78041.CD