header

Assessment of stress distribution using clip/bar attachment design in maxillary implant-supported overdentures in comparison with ball/socket attachment design : (Record no. 71910)

MARC details
000 -LEADER
fixed length control field 02609cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032259.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190511s2018 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2018.Sa.A
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Salamah Wasfi Almasry
245 10 - TITLE STATEMENT
Title Assessment of stress distribution using clip/bar attachment design in maxillary implant-supported overdentures in comparison with ball/socket attachment design :
Remainder of title 3D finite element analysis /
Statement of responsibility, etc. Salamah Wasfi Almasry ; Supervised Hamdi Abo Alfotooh , Mostafa Helmy
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم توزيع الجهد بإستخدام وصلة القضيب والمشبك في الأطقم المحموله العلويه المدعمه بالغرسات مقارنة بوصلة الكرة والتجويف :
Remainder of title : دراسة تحليل العناصر المحدودة ثلاثية الأبعاد
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Salamah Wasfi Almasry ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 126 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. Aim: Is to compare the stress distribution pattern in two different attachment systems namely: Bar\clip. And Ball\socket. In implant supported overdenture at different zones in bone surrounding dental implant with application of force with different magnitudes and directions using 3D Finite element analysis. Material & Methods: 3d model of two edentulous maxilla restored with implant supported overdenture using different attachment designs. Amount of 50, 100 and 150 N load in deferent directions (vertical and oblique) were applied through the overdenture simultaneously on posterior dentition by aid of finite element analyses software. Loads were directed toward the central fossa. Stress analysis was carried out to detect the generated stresses on bone surrounding dental implants. Results: When comparing between both attachments, the maximum Von Mises stresses in vertical loads of 50, 100, and 150 N and both 50 N oblique loads. Ball attachment shows lower stress levels at the cancellous as well as cortical bone surrounding dental implants
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term ball/socket
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term clip/bar
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Stress distribution
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hamdi Abo Alfotooh ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mostafa Helmy ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Asmaa
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2018.Sa.A 01010110078052000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2018.Sa.A 01020110078052000 22.09.2023 CD - Rom 78052.CD