MARC details
000 -LEADER |
fixed length control field |
02172cam a2200313 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
190610s2019 ua do f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.21.02.M.Sc.2019.He.E |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Hend Hassan Sayed Salem |
245 10 - TITLE STATEMENT |
Title |
Efficacy of ventilator hyperinflation versus manual resuscitator bag on mechanically ventilated patients / |
Statement of responsibility, etc. |
Hend Hassan Sayed Salem ; Supervised Zahra M. H Serry , Hany Ezzat Obaya |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
تأثير تضخم التنفس الاصطناعي مقابل تضخم كيس الإنعاش اليدوي على مرضى جهاز التنفس الصناعي |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Hend Hassan Sayed Salem , |
Date of publication, distribution, etc. |
2019 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
65 P. : |
Other physical details |
charts , photoghraphs ; |
Dimensions |
25cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (M.Sc.) - Cairo University - Faculty of Physical Therapy - Department of Physical Therapy for Cardiopulmonary and Geriatrics Disorder |
520 ## - SUMMARY, ETC. |
Summary, etc. |
Objective: the aim of this study was to compare the efficacy of ventilator hyperinflation versus manual resuscitator bag hyperinflation on mechanically ventilated patients Methods: Forty mechanically ventilated patients (30 men & 10 women) their age ranged from 40-50 years were selected from Cairo University Hospitals (185 new emergency unit) This study conducted from march 2018 to July 2018 Cairo, Egypt. The forty patients were classified into two groups equal in number ; each group consisted of twenty patients. group (A) received manual hyperinflation and traditional physiotherapy, group (B) received ventilator hyperinflation and traditional physiotherapy. Both groups would be evaluated through: amount of septum production, dynamic compliance and arterial blood gases 3 times per week, the duration of the study last for two weeks |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Manual hyperinflation |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Mechanical ventilator |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Ventilator hyperinflation |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Hany Ezzat Obaya , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Zahra M.H Serry , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Shimaa |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |