Comparison between two different techniques of manufacturing the surgical guides on accuracy of implant placement in completely edentulous patients using CBCT : (Record no. 72421)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02730cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223032315.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 180615s2018 ua dho f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.09.M.Sc.2018.Be.C |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Belal Ahmed Mohammed Mohammed |
245 10 - TITLE STATEMENT | |
Title | Comparison between two different techniques of manufacturing the surgical guides on accuracy of implant placement in completely edentulous patients using CBCT : |
Remainder of title | Randomized Clinical Trial / |
Statement of responsibility, etc. | Belal Ahmed Mohammed Mohammed ; Supervised Amal Rekaby Taha , Azza Farahat |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | دراسه مقارنة بين تقنيتين مختلفتين لتصنيع الأدله الجراحيه على دقة وضع الغرسات السنيه في حالات الفقد الكلى للأسنان باستخدام الأشعه المقطعيه المخروطيه |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Belal Ahmed Mohammed Mohammed , |
Date of publication, distribution, etc. | 2018 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 82 P. : |
Other physical details | charts , facsimiles , photoghrahs ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Background : Recently, computed tomography (CT) has been introduced for pre-surgical implant planning. Prosthetically driven implant placement using computer software may ensure precise placement and predictable prosthetic outcomes. Stereolithography and selective laser sintering had become a favorable option for fabricating surgical guides. Purpose : To compare between laser sintering & stereolithiographgic techniques for manufacturing the surgical guides on the accuracy of implants{u2019} placement in completely edentulous patients using CBCT. Material and methods : Pre operative CBCT scanning were made for the patients; while they were wearing radiographic template. After planning of the surgical guide on software, printing with either stereolithography or selective laser sintering according to the group studied. Two implants were installed in the mandibular canine-premolar areas following computer aided surgical guides. Another post-operative CBCT scan was made for the patients while wearing the same radiographic template. Superimposition of the pre-operative CBCT (virtual planning) and the postoperative CBCT after implants insertion was made |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Accuracy of implant placement |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | CBCT |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Completely edentulous |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Amal Rekaby Taha , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Azza Farahat , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Shimaa |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.09.M.Sc.2018.Be.C | 01010110078428000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.09.M.Sc.2018.Be.C | 01020110078428000 | 22.09.2023 | CD - Rom | 78428.CD |