header

Two dimensional simulation of cement clinker cooler / (Record no. 72749)

MARC details
000 -LEADER
fixed length control field 02140cam a2200313 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190710s2019 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.04.M.Sc.2019.Am.T
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Amr Mostafa Kamal Mostafa
245 10 - TITLE STATEMENT
Title Two dimensional simulation of cement clinker cooler /
Statement of responsibility, etc. Amr Mostafa Kamal Mostafa ; Supervised Omar Elfarouk Abdelsalam Hassan , Seif Eddeen khaled Fateen
246 15 - VARYING FORM OF TITLE
Title proper/short title محاكاة ثنائية الأبعاد لمبرد كلنكر الأسمنت
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Amr Mostafa Kamal Mostafa ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 84 P. :
Other physical details charts , facsimiles ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Chemical Engineering
520 ## - SUMMARY, ETC.
Summary, etc. In the present thesis, a mathematical model for cooling process inside clinker grate cooler is introduced and COMSOL multiphysics modeling software is used to simulate the temperature distribution of clinker and air inside clinker grate cooler.The proposed model showed that modeling softwares such as COMSOL could be used to simulate heat transfer between moving packed bed and air and significantly reduce the modeling efforts and the computational time when compared to ordinary methods which may use programming software such as Matlab during simulation.The proposed model could be used as a training tool for cement plant operator and as a guiding tool to improve cement plant operation.Temperature distribution of clinker and air in grate cooler were obtained and the results were validated using published data. Finally, the proposed model was used to study the effect of increasing the clinker bed height on the cooling process at same operation parameters
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Clinker cooler
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Mathematical modeling
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Simulation
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Omar Elfarouk Abdelsalam Hassan ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Seif Eddeen khaled Fateen ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.04.M.Sc.2019.Am.T 01010110078593000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.04.M.Sc.2019.Am.T 01020110078593000 22.09.2023 CD - Rom 78593.CD