header

Numerical simulation of smoke management system insprinklered car parks / (Record no. 72757)

MARC details
000 -LEADER
fixed length control field 01952cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190710s2019 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.11.Ph.D.2019.Da.N
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Dalia Essam Eldin Khalil
245 10 - TITLE STATEMENT
Title Numerical simulation of smoke management system insprinklered car parks /
Statement of responsibility, etc. Dalia Essam Eldin Khalil ; Supervised Samy Mourad Morcos , Mohamed Mahmoud Ali Hassan , Ahmed A. Fahim
246 15 - VARYING FORM OF TITLE
Title proper/short title محاكاه عددية للتحكم فى أدخنة الحرائق داخل جراجات السيارات المزودة بأنظمة اطفاء ألى
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Dalia Essam Eldin Khalil ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 127 P. :
Other physical details charts , facsimiles ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Engineering - Department of Mechanical Power Engineering
520 ## - SUMMARY, ETC.
Summary, etc. The following thesis aims to study the effect of sprinklers activation on the fire induced smoke behaviour and the interaction of water particles with the smoke layer by using Fire Dynamic Simulator (FDS 6.5.3). It was found that the sprinkler activation drastically decreased the visibility at occupant{u2019}s level. The sprinklers water particles when activated dragged the smoke layer downwards due to its momentum.Increasing the ceiling height to 3.5 m in case of impulse ventilation system and 3.2 m in case of ducted system and the sprinkler operating pressure to a minimum of 4bar may help reduce the problem
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Fire dynamic simulator
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Numerical simulation
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Sprinklered car parks
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed A. Fahim ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Mahmoud Ali Hassan ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Samy Mourad Morcos ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.11.Ph.D.2019.Da.N 01010110078599000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.11.Ph.D.2019.Da.N 01020110078599000 22.09.2023 CD - Rom 78599.CD