MARC details
000 -LEADER |
fixed length control field |
02721cam a2200325 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
190729s2018 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
Ph.D |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.09.05.Ph.D.2018.We.I |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Wessam Mohamed Magdi Ali |
245 10 - TITLE STATEMENT |
Title |
Influence of small, midi, medium and large fields of view on accuracy of linear measurements in cbct imaging : |
Remainder of title |
Diagnostic accuracy study / |
Statement of responsibility, etc. |
Wessam Mohamed Magdi Ali ; Supervised Nashwa Salah Mohamed , Enas Anter Abdalghaffar , Hanaa Mohamed Alshenawy |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
تأثيرالمجالات الصغير: الوسط :المتوسط والكبير على مدى دقة القياسات الخطية في تصويرالأشعة المقطعية ذات الشعاع المخروطى : |
Remainder of title |
دراسة الدقة التشخيصيه |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Wessam Mohamed Magdi Ali , |
Date of publication, distribution, etc. |
2018 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
106 P. : |
Other physical details |
charts , facsimile ; |
Dimensions |
25cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral (Radiology and Diagnosis) |
520 ## - SUMMARY, ETC. |
Summary, etc. |
This study aimed to evaluate the accuracy of CBCT linear measurements in different FOVs (Small, Midi, Medium and Large). This study was performed on thirteen implant bone models. On each model, at the incisors region three positions were selected, then on each of these positions three radio-opaque markers (gutta-percha pieces) were glued as; two pieces on the facial surface one occlusally and one apically, both were on the same vertical line and perpendicular to the horizontal plane, while the third one was placed on the lingual surface opposing the occlusally placed facial piece. Each sample was scanned with Cranex3Dx CBCT machine four times with four different FOVs and voxel sizes (Small: 50x50 mm with voxel size 200 æm, Midi: 61x78 mm with voxel size 300 æm, Medium: 78x78 mm with voxel size 300 æm and Large: 78x 150 mm with voxel size 350 æm). Distances between the GP pieces presented in height, thickness, and width of bone model were measured directly on the models by means of a digital caliper, and then compared with same distances measurements on CBCT images of these models obtained using distance measurement function of OnDemand3d viewer software |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Cone beam computed tomography |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Large fields of view |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Linear measurements |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Enas Anter Abdalghaffar , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Hanaa Mohamed Alshenawy , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Nashwa Salah Mohamed , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Shimaa |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |