MARC details
000 -LEADER |
fixed length control field |
02164cam a2200301 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
190902s2019 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.13.03.M.Sc.2019.As.N |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Ashraf Nader Mohi Eldeen Rizk |
245 12 - TITLE STATEMENT |
Title |
A novel approach for remote diagnosis and troubleshooting for lab instruments / |
Statement of responsibility, etc. |
Ashraf Nader Mohi Eldeen Rizk ; Supervised Ayman M. Eldeib |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
نهجٌ جديد لتحـديد الأعطال و التشخيص عن بُعد لأجهزة مختبرات التحاليل الطبية |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Ashraf Nader Mohi Eldeen Rizk , |
Date of publication, distribution, etc. |
2019 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
55 P. : |
Other physical details |
charts , facsimiles ; |
Dimensions |
30cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (M.Sc.) - Cairo University - Faculty of Engineering- Department of Systems and Biomedical Engineering |
520 ## - SUMMARY, ETC. |
Summary, etc. |
The use of remote diagnosis and troubleshooting are widely used nowadays to improve instruments{u2019} uptime and minimize workflow interruption. However, such feature is not used in many critical care units or laboratories (labs) either due to limited features offered by manufacturers or high cost of the interface S/W especially in developing countries. The negative impact is more obvious in aged or discontinued machines lacking remote communication ports despite owning an embedded diagnosis or troubleshooting S/W. This research describes a direct access remote diagnosis and troubleshooting for the input and output devices of a critical care/lab instrument using a flat data cable, a 5.5cm x 10cm Arduino Due ready-made board, and a control S/W. The main advantage of this approach is its low cost, compact design and simple implementation besides being convenient and suitable for other instruments possessing in/out devices with the same specifications |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Critical care instruments |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Direct access remote diagnosis |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Laboratory equipment |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Ayman M. Eldeib , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Shimaa |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |